Vela (V-Prism 30): an equilateral colour prism with cone-response lightness and arc-length hue sampling

Status: Closed-form mathematical specification and pure-physiology numerical verification under the joint premises of Ariclue Papers 1–3; human cross-hue matching of the equilateral aspect ratio k = √3/2 and perceptual arc-length step remains open for empirical measurement.

Abstract

Conventional colour models represent hue on a circular wheel of circumference 2π (360°) and treat hue stepping as uniform angular division (n·c = 360°). When the three physiological premises established in companion Papers 1–3 hold simultaneously—(1) cone-response lightness V(I) = Iⁿ / (Iⁿ + σ_Rⁿ) with n = 0.74 and 30:1 geometric-mean half-saturation σ_R = 1/√30 (Paper 1); (2) spatial–lightness quantisation q_code = 1/N and the photopic Barlow additive dark-light floor δ = μ_dark/κ = 0.03205 at 200 cd/m² white (Paper 2); and (3) a zero-saturation Black–White spine (S = 0) with a 60° equilateral triangular cross-section and zero-fit physiological Hunt–Pointer–Estevez (HPE-LMS) opponent coordinates normalised by physical Rösch–MacAdam cardinal spans (Paper 3)—the resulting colour solid is a straight triangular prism whose native coordinates and hue-stepping grammar require no π and no trigonometric functions. This standalone physiological colour model, named Vela (V-Prism 30) (short: Vela), uses zero matrices or coordinates borrowed from OKLab or CIELAB and is released openly under CC0 1.0 (specification) and MIT (reference code).

Each Vela colour is indexed by (u, a, b): a piecewise-linear 6-edge gamut-ridge parameter u ∈ [0, 6), cone-response lightness b = L_V(Y) ∈ [0, 1] inverted in closed form to physical relative luminance Y(b), and coupled chromatic amplitude 0 ≤ a ≤ 2·min(b, 1 − b) giving relative saturation S = a / [2·min(b, 1 − b)] ∈ [0, 1] for 0 < b < 1, with S = 0 defined separately at b ∈ {0, 1}. Hue stepping is governed by physiological chromatic arc length s(u; a, b) integrated in span-normalised HPE-LMS + V_Barlow opponent space (S_ref = S_total(1.0, 0.50) = 2.0810, mapped to 30.00/30) rather than circular angle. Five theorems and one corollary prove exact luminance and gamut invariance (max |Y − Y(b)| = 9.55 × 10⁻⁸ across 10,692 samples), neutral-spine collapse, 2.94–5.36× anisotropy of equal-angle stepping eliminated by arc-length inversion, coupled saturation–lightness capacity ceilings, a uniform relative-saturation index at fixed lightness b and shared constant α on the outer shell, and physical-cusp loop fracture with a Yellow-to-Blue limiting crossover between b = 0.40 and b = 0.50. An optional external double-cone visual embedding (equation (11)) re-introduces sin/cos strictly for 3D cylindrical visualisation and never enters Vela’s native coordinates, reconstruction, or sampling grammar.

1. Introduction

Cylindrical and polar colour spaces (HSL, HSV, CIELCH, OKLCH) inherit a circular assumption: hue is an angle H ∈ [0°, 360°) and generating n equally spaced colours divides 2π by n. That convention conflates angular position with physiological chromatic distance. On a real physical gamut slice at fixed lightness, the physiological opponent path length between adjacent primaries varies by 2.94× to 5.36× (Table 2); stepping by fixed angle ΔH = 360°/n crowds yellow–green hues while stretching blue–magenta and magenta–red intervals.

Vela (V-Prism 30) resolves this structural mismatch by constructing a single closed-form colour solid and palette-generation grammar directly from the physiological premises of Papers 1–3, without borrowing any fitted matrix or cube-root lightness curve from OKLab or CIELAB. The name V-Prism 30 records its three foundations: V for the Naka–Rushton cone-response function V(I) with Barlow dark light, Prism for the straight 60° equilateral triangular solid whose native geometry and sampling are strictly π-free, and 30 for the 30:1 material reflectance range and the 30-unit normalised chromatic arc-length scale.

2. Axioms and definitions

Vela introduces no fitted empirical free parameters beyond the physiological and physical constants fixed in Papers 1–3:

• Cone-response lightness (Paper 1): reflectance range R = 30, half-saturation midpoint σ_R = 1/√30 ≈ 0.182574, cone exponent n_cone = 0.74.

• Photopic Barlow dark-light floor (Paper 2, Table 8): δ = μ_dark/κ = 0.032054 at 200 cd/m² reference white, adapting luminance L_A = 50 cd/m², Watson–Yellott unified pupil diameter D = 3.2034 mm, c_td = 12 R* cone⁻¹ s⁻¹ td⁻¹, and macaque dark light 620 R*/s.

• Pure physiological opponent plane (Paper 3): D65-normalised Hunt–Pointer–Estevez cone excitations (L, M, S) transformed by V_Barlow into a_raw = V_Barlow(L) − V_Barlow(M) and b_raw = ½[V_Barlow(L) + V_Barlow(M)] − V_Barlow(S), normalised with zero free parameters by physical Rösch–MacAdam D65 cardinal spans span_a = 0.2367 and span_b = 0.9850 (ratio 4.162×).

• Equilateral prism cross-section (Paper 3): aspect ratio k = A/H = √3/2 ≈ 0.866025 (apex angle 60.0°), zero-saturation Black–White spine S = 0, and relative-saturation index E_W = √[(1 − b)² + (α·S)²] (illustrative constant α = 1.94).

3. Complete mathematical formulation

All native Vela equations (1)–(10) are strictly π-free and use no trigonometric functions.

3.1 Cone-response lightness and exact inverse luminance

V(I) = I^0.74 / (I^0.74 + σ_R^0.74), σ_R = 1/√30, I_eff = Y + δ b = L_V(Y) = [V(Y + δ) − V(δ)] / [V(1 + δ) − V(δ)] ∈ [0, 1](1)

With δ = 0.032054, V(δ) = 0.216292, V(1 + δ) = 0.782754, and response span ΔV = 0.566463. Inverting equation (1) yields exact closed-form relative luminance:

Y(b) = max(0, σ_R · [V_b / (1 − V_b)]^(1/0.74) − δ), V_b = V(δ) + b·ΔV b_m = L_V(B + (m / N)·(W − B)), m = 0, 1, …, N (default N = 30)(2)

At b = 0.50 under fixed σ_R = 1/√30 = 18.26 % (distinct from the dark-offset re-optimised effective input scale 0.2598, physical input 22.77 %), Y = 15.01 % so I_eff = Y + δ = 18.21 %.

3.2 Coupled equilateral cross-section

0 ≤ a ≤ a_max(b) = 2·min(b, 1 − b)(3)
S(a, b) = a / [2·min(b, 1 − b)] ∈ [0, 1] (0 < b < 1; S = 0 for a = 0 or b ∈ {0, 1})(4)

3.3 π-free 6-edge gamut ridge and exact luminance reconstruction

P(u) = (1, u, 0) [0,1) · (2−u, 1, 0) [1,2) · (0, 1, u−2) [2,3) · (0, 4−u, 1) [3,4) · (u−4, 0, 1) [4,5) · (1, 0, 6−u) [5,6)(5)
c_max(u, Y) = (Y / Y_P)·P(u) if Y ≤ Y_P; else P(u) + [(Y−Y_P)/(1−Y_P)]·(1−P(u)) c(u, a, b) = (1 − S(a, b))·(Y, Y, Y) + S(a, b)·c_max(u, Y), Y = Y(b)(6)

3.4 Physical-cusp ceiling and pure-physiology opponent arc length

a_max^cusp(u, b) = C_phys(c_max(u, Y(b))) / C_phys(P(u)) U(a, b) = { u ∈ [0, 6) : a ≤ a_max^cusp(u, b) }(7)
ã(c) = [V_Barlow(L) − V_Barlow(M)] / span_a, span_a = 0.2367 b̃(c) = [½(V_Barlow(L) + V_Barlow(M)) − V_Barlow(S)] / span_b, span_b = 0.9850(8)
s(u; a, b) = ∫₀ᵘ √[(dã/dt)² + (db̃/dt)²] dt, S_total(a, b) = s(6; a, b) c₃₀ = 30 · (c / S_ref), S_ref = S_total(1.0, 0.50) = 2.0810(9)
u_i = s⁻¹(s₀ + i·c), i = 0, 1, …, n − 1 n·c = S_total(a, b) (Closed); (n − 1)·c ≤ S_seg (Open)(10)

3.5 Optional external double-cone visual embedding and visibility metrics

Strictly external to Vela’s native π-free coordinates, reconstruction, and sampling (equations (1)–(10)), the straight prism curls continuously into Paper 3’s double cone for 3D visual inspection via:

p_H = (ρ(k) + r)·sin(2π·k·u_c), p_S = (ρ(k) + r)·cos(2π·k·u_c) − ρ(k), ρ(k) = W(1−k)/(πk) E_W = √[(1 − b)² + (1.94·S)²], H_L = min(b, 1 − b)(11)

Trigonometric functions and π enter exclusively in this optional 3D curl projection (p_H, p_S) and never appear in equations (1)–(10).

4. Formal theorems and corollaries

• Theorem 1 (Exact relative luminance and sRGB gamut invariance). For every Vela triplet (u, a, b) with u ∈ [0, 6), b ∈ [0, 1], and 0 ≤ a ≤ 2·min(b, 1 − b), c(u, a, b) of equation (6) satisfies c ∈ [0, 1]³ strictly and rel_Y(c) = Y(b) identically (global verification across 10,692 samples: max |Y − Y(b)| = 9.55 × 10⁻⁸, bounded strictly by 7-digit IEC sRGB coefficient rounding).

• Theorem 2 (Neutral-spine collapse at zero saturation or luminance extremes). As a → 0⁺, b → 0⁺, or b → 1⁻, S_total(a, b) → 0 and every hue collapses onto (Y(b), Y(b), Y(b)), reducing distinct colour capacity to n_max = 1.

• Theorem 3 (Anisotropy of angular stepping vs arc-length equidistance). Equal ridge-parameter or angular steps Δu = 6/n produce up to 5.36× physiological step distortion across the six gamut edges (5.36× at b = 0.25, 3.51× at b = 0.50, 2.94× at b = 0.75; Table 2). Inverting equation (9) via u_i = s⁻¹(s₀ + i·c) eliminates this distortion without π.

• Theorem 4 (Coupled saturation–lightness capacity ceiling). At fixed lightness b, maximum physiological chromatic perimeter S_total(a_max(b), b) peaks near mid-grey (b = 0.50, S_full = 2.0810 = 30.00/30) and contracts toward both poles (14.01/30 at b = 0.10; 15.47/30 at b = 0.90; Table 1).

• Theorem 5 (Uniform relative-saturation index at fixed lightness b and constant α). At any fixed lightness b on the outer prism shell a = 2·min(b, 1 − b) (S = 1), under a shared cross-hue constant α (illustrative α = 1.94; if α(H) varies with hue as allowed in Paper 3, cross-hue equality no longer holds automatically), all n sampled colours share identical relative saturation difference ΔS = 1.00, dual-ground headroom H_L = min(b, 1 − b), and relative-saturation index E_W(b, 1) = √[(1 − b)² + α²] (with α = 1.94, varying with b from 2.139 at b = 0.10 to 1.943 at b = 0.90). This is a structural check on the construction; as Paper 5 demonstrates, E_W tracks relative saturation S rather than model-predicted opponent-channel response C̃ (which still varies across hues and approaches 0 as b → 1), motivating Paper 6’s palette screening score V_vis = (1 − b) + 1.94·C_p (design parameters).

• Corollary 6 (Physical-cusp loop fracture and Yellow–Blue limiting crossover). Under equation (7), the ridge-normalised physical chroma fraction a_max^cusp(u, b) achieves a closed-loop minimum a_loop(b) = min_u a_max^cusp(u, b) limited by Yellow for b ≤ 0.40 (0.161 at b = 0.10, 0.389 at b = 0.25, 0.596 at b = 0.40) and by Blue for b ≥ 0.50 (0.655 at b = 0.50, 0.497 at b = 0.60, 0.291 at b = 0.75, 0.109 at b = 0.90). Requiring uniform ridge-normalised physical chroma above a_loop(b) fractures the closed loop into open feasible segments (n − 1)·c ≤ S_seg, whereas relative-saturation sampling via equation (6) stays strictly inside [0, 1]³ for all S ∈ [0, 1].

5. Quantitative verification

All values in Tables 1–3 are computed strictly in pure physiological HPE-LMS + V_Barlow with zero fitted parameters and zero OKLab or CIELAB matrices.

Table 1 | Vela lightness-slice geometry, chromatic path lengths (0–30 scale and raw Δs), and physical-cusp ceilings

b Y (%) I_eff (%) a_max S_full (raw / 30) S_half (raw / 30) a_loop (lim.) E_W
0.10 1.65 4.86 0.20 0.9721 (14.01) 0.5580 (8.04) 0.161 (Y) 2.139
0.25 5.08 8.29 0.50 1.7431 (25.13) 0.9898 (14.27) 0.389 (Y) 2.080
0.40 10.18 13.39 0.80 2.0476 (29.52) 1.1107 (16.01) 0.596 (Y) 2.031
0.50 15.01 18.21 1.00 2.0810 (30.00) 1.0832 (15.62) 0.655 (B) 2.003
0.60 21.56 24.77 0.80 2.0619 (29.72) 1.0260 (14.79) 0.497 (B) 1.981
0.75 36.79 40.00 0.50 1.5520 (22.37) 0.7029 (10.13) 0.291 (B) 1.956
0.90 64.97 68.18 0.20 1.0728 (15.47) 0.4085 (5.89) 0.109 (B) 1.943

Note: Pure physiological HPE-LMS + V_Barlow (δ = 0.032054, span_a = 0.2367, span_b = 0.9850); S_ref = 2.0810 maps to 30.00/30.

Table 2 | Per-edge physiological chromatic arc lengths (HPE-LMS + V_Barlow, span-normalised, outer shell S = 1)

b R→Y Y→G G→C C→B B→M M→R Total Max/Min
0.25 0.2972 0.0930 0.1412 0.3958 0.4984 0.3175 1.7431 5.36×
0.50 0.4265 0.1371 0.2482 0.3431 0.4442 0.4818 2.0810 3.51×
0.75 0.4186 0.1422 0.3135 0.2214 0.2314 0.2249 1.5520 2.94×

Note: Each edge integrated over 200 line-integral segments (M = 1,200 per loop). Equal angular stepping distorts chromatic intervals by 2.94×–5.36×.

Table 3 | Worked 6-colour Vela benchmark palette (b = 0.50, a = 0.80, Closed, S_total = 24.02/30, c = 4.00/30)

# Edge (u) sRGB Hex Arc s_30 (raw) Linear RGB |Y − Y(b)| E_W / H_L
1 R (0.000) #CB3030 0.00/30 (0.000) (0.594, 0.030, 0.030) 3.00e-09 1.63 / 0.50
2 R→Y (0.502) #866730 4.00/30 (0.278) (0.240, 0.135, 0.030) 3.00e-09 1.63 / 0.50
3 G→C (2.442) #307959 8.01/30 (0.555) (0.030, 0.191, 0.101) 3.00e-09 1.63 / 0.50
4 C→B (3.834) #3067D4 12.01/30 (0.833) (0.030, 0.134, 0.659) 3.00e-09 1.63 / 0.50
5 B→M (4.347) #9734EB 16.02/30 (1.111) (0.310, 0.034, 0.830) 3.39e-09 1.63 / 0.50
6 M→R (5.460) #BD3092 20.02/30 (1.389) (0.507, 0.030, 0.288) 3.00e-09 1.63 / 0.50

Note: Maximum relative luminance invariance error across the 6 swatches is 3.39 × 10⁻⁹; global Theorem 1 grid max error across 10,692 samples is 9.55 × 10⁻⁸.

Fig. 1 | 6-colour Vela benchmark palette (b = 0.50, a = 0.80, Closed, c = 4.00/30)

#CB3030R · s=0.0
#866730R → Y · s=4.0
#307959G → C · s=8.0
#3067D4C → B · s=12.0
#9734EBB → M · s=16.0
#BD3092M → R · s=20.0
Every swatch holds exact relative luminance Y = 15.01 % (|ΔY| ≤ 3.39 × 10⁻⁹) and equal physiological HPE-LMS + V_Barlow arc interval c = 4.00/30, skipping the narrow Y→G edge automatically.

6. Comparison with prior colour spaces

Table 4 | Structural comparison of Vela against established colour spaces

Space Lightness basis Chromatic basis Solid geometry Hue stepping a–b coupling Gamut safe
HSL / HSV (M+m)/2 (non-lum.) RGB hexcone Cylinder / cone Circular 360°/n Artificial Yes
CIELCH CIE L* (Y^1/3 + toe) Fitted a*b* Irregular solid Circular 360°/n Uncoupled Clips
OKLCH OKLab L (Y^1/3) Fitted LMS matrix Irregular solid Circular 360°/n Uncoupled Clips
NCS Phenomenological 4-pole opponent Equilateral bicone 4-quadrant 400 w + s + c = 1 Atlas only
Vela (VP-30) V_Barlow (n=0.74, δ=0.032) HPE-LMS + V_Barlow 60° Straight Prism π-free Arc Δs a ≤ 2·min(b,1−b) Exact 100%

Note: Vela uses zero fitted opponent matrices or cube-root curves from OKLab or CIELAB.

7. Testable predictions and limitations

7.1 Testable predictions and falsification criteria

• Arc-length equidistance vs circular angle: At fixed lightness b = 0.50 and a = 0.80, observers will judge the 6-colour arc-length palette of Table 3 to have lower adjacent-step variance than a uniform Δu = 1 or ΔH = 60° ring; persistent preference for equal-angle stepping falsifies Theorem 3.

• Dark-end luminance match with Barlow floor: At 200 cd/m² white and L_A = 50 cd/m², bisection middle grey (b = 0.50) is predicted near Y = 15.01 % (I_eff = 18.21 %) under full photopic dark-light calibration, shifting systematically toward 18.26 % as δ → 0 at higher adapting luminance.

• Physical-cusp Yellow–Blue crossover: Constant-chroma closed-loop matching should hit a Yellow gamut ceiling at dark slices (b ≤ 0.40) and switch to a Blue ceiling at b ≥ 0.50 (Corollary 6).

7.2 Assumptions and limitations

• Gamut anchor: Equations (5)–(6) construct Vela on sRGB; extending to Display P3, Rec. 2020, or the D65 MacAdam optimal solid replaces only P(u) and rel_Y.

• Physiological parameters: n = 0.74 and 620 R*/s dark light come from macaque recordings (Papers 1–2); human in-vivo calibration remains open.

• Cross-hue metric weight: Direct 30:1 white-ground human matching of α(H), equilateral aspect ratio k = √3/2, and whether chromatic arc length needs an observer-fitted opponent weight beyond the zero-fit Rösch–MacAdam 4.162× span ratio remain to be measured.

8. Methods

All values in Tables 1–3 and the global Theorem 1 invariance check were computed in Python 3.14.6 (standard library only, paper4_vela_pure_physiology_20261126.py) using double-precision arithmetic with M = 1,200 line-integral segments per loop (200 per gamut edge) and monotone binary-search inversion of s(u; a, b). Global invariance was tested on 10,692 triplets across b ∈ [0.05, 0.95], S ∈ [0, 1], and u ∈ [0, 6). Zero external packages and zero OKLab or CIELAB matrices were used.

Declarations

• Data and code availability: The Vela (V-Prism 30) specification is released under CC0 1.0 Public Domain and the reference implementation under the MIT licence (github.com/ariclue/Laboratory).

• Competing interests: The author declares no competing interests.

• Use of generative AI: Generative AI tools were used during the preparation of this work (Claude Opus 5.5, Anthropic; GPT-6.2 Sol, OpenAI; Gemini 4 Neon, Google). After using these tools, the author reviewed, verified and edited the content as needed and takes full responsibility for the content of this paper.

References

1. Alchemist, H. A geometric-mean prediction for middle grey from a cone-response model. Ariclue research (2026). doi:10.5281/zenodo.24540310

2. Alchemist, H. A spatial sampling model of lightness discrimination under optical blur. Ariclue research (2026). doi:10.5281/zenodo.24540335

3. Alchemist, H. Saturation difference from a zero-saturation anchor in a prism model of colour and lightness. Ariclue research (2026). doi:10.5281/zenodo.24540340

4. Valeton, J. M. & van Norren, D. Light adaptation of primate cones: an analysis based on extracellular data. Vision Res. 23, 1539–1547 (1983). doi:10.1016/0042-6989(83)90167-0

5. Barlow, H. B. Retinal noise and absolute threshold. J. Opt. Soc. Am. 46, 634–639 (1956). doi:10.1364/JOSA.46.000634

6. MacAdam, D. L. Maximum visual efficiency of colored materials. J. Opt. Soc. Am. 25, 361–367 (1935). doi:10.1364/JOSA.25.000361

7. Newhall, S. M., Nickerson, D. & Judd, D. B. Final report of the O.S.A. Subcommittee on the spacing of the Munsell colors. J. Opt. Soc. Am. 33, 385–418 (1943). doi:10.1364/JOSA.33.000385

8. Stockman, A. & Sharpe, L. T. The spectral sensitivities of the middle- and long-wavelength-sensitive cones derived from measurements in observers of known genotype. Vision Res. 40, 1711–1737 (2000). doi:10.1016/S0042-6989(00)00021-3

9. Hård, A. & Sivik, L. NCS—Natural Color System: a Swedish standard for color notation. Color Res. Appl. 6, 129–138 (1981). doi:10.1002/col.5080060303

10. Valdez, P. & Mehrabian, A. Effects of color on emotions. J. Exp. Psychol. Gen. 123, 394–409 (1994). doi:10.1037/0096-3445.123.4.394

11. IEC 61966-2-1:1999. Multimedia systems and equipment — Colour measurement and management — Part 2-1: Colour management — Default RGB colour space — sRGB (1999).