A spatial sampling model of lightness discrimination under optical blur

Abstract

This paper integrates the cone-response lightness scale of Paper 1, optical-blur spatial sampling, and the equilateral colour-section geometry of Paper 3 as one joint model. The first supplies the cone response and the geometric-mean middle of a specified black–white range. Optical blur and area counting give the coding step q_code = (b/C)² for binary, equal-weight elements in two dimensions. The third study supplies the equilateral cross-section ratio k_vis = √3/2 as a pre-specified candidate near-black visual exponent, whose link to empirical visual thresholds is tested by experiment. At fixed viewing conditions the candidate law is q_vis(b) = Q₀(b/b₀)^k_vis, where Q₀ is the threshold at reference blur b₀. If this pre-specified exponent applies to near-black discrimination with all else fixed, doubling blur b increases the model threshold by 2^(√3/2) ≈ 1.823×, against 2× for a linear model (k = 1) and 4× for area counting (k = 2). The same law constrains the ratio of noise to response gain in the weighted cone readout. With a shared model calibration at 1,000 cd/m², the visual-threshold join reduces the CIE L* root-mean-square residual below Y = 0.1 by 68.6%, 68.0% and 55.8% at 0, 0.125 and 0.25 D of geometric defocus. These are conditional calculations against a published scale. The experiment tests absolute thresholds and the predicted changes with blur under one task.

Introduction

The observation

A black-and-white photograph, film or television picture holds no colour, yet a scene in it keeps its objects, their shapes and their distances. A pen drawing holds two values, ink and paper, yet hatching gives it greys. A printed photograph is made of dots of one ink on one paper; when the dots are small, the eye takes the patterned areas as smooth tones¹. A painter's notebook of about 1490–1516 states that an object rendered in white and black shows stronger relief than in any other way². In each case lightness is the only carrier, and in the printed and drawn cases a grey is itself made of space: of the share of an area that is covered.

From grey response to a joint model

The three studies contribute different parts of the same calculation. The first defines V(I) and sets its half-response input to the geometric mean of the specified black and white endpoints. The second computes the optical blur, the number of spatial elements in a reading cell and the pooled response. The third supplies the equilateral colour-section ratio √3/2. We adopt that value as the exponent for near-black visual discrimination under fixed conditions. This is the joint model assumed throughout the paper. The halftone calculation identifies the coded step. The visual exponent determines how the discrimination threshold changes with blur, with its absolute scale set by a reference threshold in the same task. We evaluate the older optical and halftone calculations alongside the consequences of the joint model.

Definitions

  • Sampled variable: relative luminance Y(x) (written I(x) = L(x)/L_white when entered into the cone response of ref. 3) of a surface image, white = 1, black → 0, over a field of position x in degrees of visual angle.
  • Absolute luminance and adapting background: physical luminance L (cd/m²) and the adapting field luminance L_A (cd/m²) are kept distinct from relative luminance I = L/L_white. A dark patch with low relative luminance (for example I = 1/30) can sit inside a bright photopic surround (for example L_A = 50–100 cd/m²). Photon capture per cone depends additionally on absolute luminance, spectral power distribution, pupil area, presentation duration T and intraocular scatter (veiling glare).
  • Spatial sampling interval: a, the size of the smallest element whose value is read on its own. For the eye three values are used: the diffraction angle θ = 1.22 λ/D of a pupil of diameter D (equation (1) of ref. 3), the anatomical foveal cone spacing s_cone of 0.50–0.58′ given there³, and the width b of optical blur; s denotes the effective optical/readout sampling interval (1.0′ at acuity 1.0) separately from anatomical s_cone.
  • Reading cell: C, the extent over which elements are pooled into one perceived lightness. C is a length; the cell has d dimensions that grow with C.
  • Lightness sampling interval: q_code is the luminance step the arrangement can encode, normalised to the black–white span. In the joint near-black model, q_vis is the luminance increment relative to reference white at 75% correct in a two-interval forced-choice task. Q₀ and b₀ denote the visual threshold and blur width at the reference condition. The visual exponent is k_vis = √3/2.
  • Signal to be recovered: the lightness of the cell, from its pooled Y or weighted cone responses.
  • Reconstruction rule: area mixing in the deterministic equal-weight model, where the cell value is the area-weighted mean of its elements (equation (1)), generalised to spatially weighted cone pooling in the noisy readout model (equation (6)).
  • Tone: the lightness of a cell made of smaller elements, as in printing; a step in tone is a lightness step.
  • Sharpness: the narrowness of the blur in the image of an edge; the blur width enters as the element a when it exceeds the cone spacing.
  • Spatial relation: the relation between forms that have thickness (volume, relief) and the depth between them. The criterion is thickness. Ordinal depth order (overlap, stacking, registers) ranks flat figures from front to back; the figures have no thickness, and the order carries no depth between them, so it is not spatial relation.

The exchange rule

Area mixing

In halftone printing the reflectance of a tint is the area-weighted mean of the reflectances of ink and paper; this is the Murray–Davies relation⁵. Light that spreads inside the paper changes the effective mixture; the Yule–Nielsen form applies the mean to R^(1/n) and returns to the linear mean for n = 1 (refs 5, 6). With N elements of luminance Yᵢ in one cell,

Y_cell = (1/N) Σ Yᵢ(1)

The mean is linear in Y, which is consistent under the model with the linear dark-end toe of ref. 4.

Counting levels

A binary printer of resolution A dots per inch with a halftone screen of L lines per inch builds each cell from (A/L)² dots, so the cell can show (A/L)² + 1 grey levels⁷˒⁸; with g equally spaced levels per equal-area, equal-weight dot the count is (A/L)²(g − 1) + 1 (ref. 9). Written with the element a and the cell C, for a cell of d dimensions and N = (C/a)^d equal-area, equal-weight elements each taking g equally spaced levels,

G = (C/a)^d (g − 1) + 1, q_code = (a/C)^d / (g − 1)(2)

With N equal binary elements, filling one more element changes the coverage by 1/N and the mean luminance of the cell by (W − B)/N, so q_code in equation (2) is normalised to the black–white range [B, W]. Relative to white the luminance step is (1 − B/W) times q_code: for a 30:1 range (B/W = 1/30), a q_code = 1/30 binary area step equals (29/30)/30 ≈ 0.03222 relative to white. Throughout this paper, the three threshold coordinates are kept distinct: q_code is a normalised luminance-range fraction, ΔV = 1/30 in the blur-onset stage is a criterion in raw cone response V(I), and boundary ΔL₁ = 0.030 (ref. 3) is in OKLab lightness. The exponent d is the number of dimensions of the cell, not a choice: it counts how many elements fit in the cell. On a square, hexagonal or any other two-dimensional lattice only the constant changes, not the exponent. q_code is a property of the code. The visual step q_vis likely follows q_code when the elements lie below the resolving limit and the reading cell is the area over which they are pooled. The numerical comparisons below examine where this holds, while the within-task human test is proposed under Predictions.

Ordered and random elements

Equation (2) counts levels of ordered elements, as in a halftone cell or an ordered dither, where a 4 × 4 matrix gives 17 patterns¹⁰. When the elements are random, the step that can be read is a standard deviation and falls with the square root of the count. Photographic film is a documented case: the product of the RMS granularity and the square root of the measuring aperture area is nearly constant (Selwyn)¹¹, so the precision of tone grows with the linear size of the aperture. Detection thresholds show both regimes: below a critical size threshold falls in proportion to area (Riccò)¹², and above it with a log–log slope near −0.5, the square root of area (Piper)¹³.

The exponent k

For a reading cell of fixed size C and an element that grows with the pupil-limited angle θ, equation (2) gives

q(θ) = q₀ (θ/θ₀)^k, q₀ = (θ₀/C)^k / (g − 1)(3)

For ordered elements in a two-dimensional reading cell, k = d = 2 follows from area counting. A one-dimensional hatching cell gives k = 1. In the random two-dimensional case, independent fluctuations scale as N^(−1/2) = a/C. These scalings describe the code and the fluctuations of the pattern. The joint visual readout uses k_vis = √3/2 for the effect of blur on near-black discrimination. The symbol k in equation (3) is the coding exponent.

The interchange in both directions

Halftone grey levels

Table 1 | Grey levels of a binary halftone cell, area (k = 2) and length (k = 1).

Printer / screen Levels (C/⁠a)² + 1 Step (a/⁠C)² Levels (C/⁠a) + 1
600 dpi / 100 lpi 37 0.0278 7
600 dpi / 120 lpi 26 0.0400 6
600 dpi / 200 lpi 10 0.1111 4
1,200 dpi / 150 lpi 65 0.0156 9
2,400 dpi / 150 lpi 257 0.0039 17

The area count agrees with the published examples (26 levels at 600/120 and 10 at 600/200; ref. 8) and with enumeration of the coverages of each cell. One published worked example gives 61 levels for 600 dpi at 100 lpi⁷; by the square rule (600/100)² + 1 is 37, and a 60 lpi screen at 600 dpi gives (600/60)² + 1 = 101 levels rather than 61. In print, k = 2 holds by construction.

Screen ruling at the resolving limit

Table 2 | Halftone screen rulings in cycles per degree at near viewing distances.

Ruling and use 250 mm (c/⁠deg) 350 mm (c/⁠deg) 400 mm (c/⁠deg)
65 lpi, newsletters¹⁴ 11.2 15.6 17.9
85 lpi, newspapers¹⁴ 14.6 20.4 23.4
133 lpi, four-colour magazines¹⁴ 22.8 32.0 36.6
150 lpi 25.8 36.1 41.2
177 lpi, art books¹⁴ 30.4 42.6 48.7

The 250 mm distance is the illustrative example used in the informative Annex A.2 of the DICOM Grayscale Standard Display Function¹⁵; 350 and 400 mm are a comparison band chosen here. Fine rulings (133–177 lpi) sit at or above 30 cycles per degree at 350–400 mm, where a cell is near one 2′ cycle and its dots are not resolved; at 250 mm only 177 lpi reaches it; coarse rulings for newsprint sit below it and are viewed farther away or accepted as visible. This is consistent in direction with spatial and lightness sampling being one quantity; the viewing distances are not stated by the print sources, so it is not a measurement of where tone replaces structure.

Contrast thresholds

Under equation (2), structure at frequency u is read in a cell of half a period, and the element is the half period at the cutoff frequency u_c, so C/a = u_c/u and the threshold step is q(u) = (u/u_c)^d/(g − 1). Thresholds were computed from the Barten (1999) contrast sensitivity model in its published implementation¹⁶˒¹⁷, for a 2° field. The model includes photon and neural noise, the optical transfer of the eye and spatial integration, so its thresholds are not a count of elements; the comparison is in form.

Table 3 | Barten thresholds against the element–cell count.

Luminance (cd/⁠m²) Cutoff u_c (c/⁠deg) u/⁠u_c Threshold contrast Binary q, k = 2 / 1 Implied g − 1, k = 2 / 1
80 43.1 0.25 0.0036 0.0625 / 0.25 17.3 / 69.3
80 43.1 0.375 0.0069 0.1406 / 0.375 20.4 / 54.5
80 43.1 0.50 0.0148 0.25 / 0.50 16.9 / 33.8
80 43.1 0.75 0.0948 0.5625 / 0.75 5.9 / 7.9
8 37.6 0.25–0.50 0.0062–0.0225 — 10.1–12.5 / 22.3–40.5
500 46.9 0.25–0.50 0.0032–0.0136 — 18.3–22.6 / 36.7–78.2

With binary elements (g = 2) under the stated conversion, binary coding predicts higher thresholds than the Barten scenario: 6–78 times higher across the displayed rows of Table 3 (5.9–69.3 at 80 cd/m², and 3.7–78.2 across the full computed 8–500 cd/m² grid, reaching 78.2× at 500 cd/m²). Under the assumed cell, threshold criterion and contrast conversion, the binary counting model underpredicts the eye's multi-level contrast sensitivity rather than proving non-binary anatomy, and g − 1 acts as an effective count parameter. Over 0.25–0.50 u_c a least-squares fit gives a log–log slope of 2.01 at 80 cd/m² (1.59 over 0.25–0.375 and 2.65 over 0.375–0.50 u_c; 1.83 at 8 and 2.06 at 500 cd/m², with sub-band fitted slopes running from 1.46 to 2.71 across 8–500 cd/m² and point derivatives running from 1.06–1.15 at 0.25 u_c to 2.96–3.33 at 0.50 u_c), so k = 2 holds as an average within that band, not as a local law. Read the other way, the thresholds give the number of levels each element would need, an effective parameter under a stated conversion. Taking the Michelson contrast m itself as the step gives 17–20 at 80 cd/m² under k = 2 and 34–69 under k = 1. The peak-to-trough luminance difference relative to white is 2Ȳm, with Ȳ the grating's mean relative luminance (relative to the black–white range it is 30/29 of this, shifting the counts below by about 3 %); with Ȳ = 1/√30 the implied g − 1 under k = 2 becomes 46–56 at 80 cd/m² (28–34 at 8 and 50–62 at 500 cd/m²). The conversion leaves the slope unchanged and moves the count. Below a quarter of the cutoff and above a half the implied count falls under both exponents, where lateral inhibition and optical blur dominate the model.

Letter acuity and contrast

Letter acuity shows the same exchange from the side of lightness. In 21 adults on a 228 cd/m² background, letter acuity was −0.18 logMAR at a Weber contrast of −90 %, 0.07 at −10 % and 0.20 at −5 % (ref. 18): as the lightness step falls, the letter must span more elements. Written as contrast ∝ size^(−k), these give k ≈ 3.8 between −90 % and −10 % and k ≈ 2.4 between −10 % and −5 %, steeper than the area exponent near the acuity limit. The direction of the exchange holds over the range measured, with an exponent near 2 only between a quarter and a half of the cutoff and under complete summation; its local value follows the contrast sensitivity function. Halftone texture shows the opposite direction, samples traded for lightness, and a limit to it: patterns at an effective 43 dpi¹⁹ read as smooth tone beyond 3.0–5.1 m (10–17 ft, the 5th and 95th percentiles for the tested patterns), while texture becomes visible closer than those distances; at those percentiles one pixel pitch subtends 0.68′ and 0.40′, respectively, so texture is still detected below the 1′ element.

Lines and areas

A sharp boundary between two large uniform areas carries its signal with a step of ΔL₁ = 0.030, while the same edge drawn as a 1 px line needs ΔL₂ ≈ 0.07 to carry the same signal (0.0625–0.0758 for the two models and viewing distances used)³, a factor of 2.1–2.5. A line offers far fewer samples across it than an area, and a larger lightness step makes up for them: fewer spatial samples are traded for a larger lightness step, the direction the interchange gives. The size of the factor comes from the contrast sensitivity model and is not derived from equation (2); the data show this direction for lines, letters and the Barten thresholds, while the opposite direction, samples traded for lightness, is shown by the halftone count.

Consequences: 1/30 and 1/60

Where the black end may sit

The question is whether the black end of a lightness scale read by the eye can be read from the sampling side: where the first lightness step above black falls for the elements and reading cells that the eye is known to use.

The black end as the first resolvable step

Table 4 uses the area-count benchmark. Equating the first coded step above absolute black to a putative black endpoint gives B/W = q_code = (a/C)^k for binary elements. The table takes a = 1′ and compares proxy reading cells. In the joint visual model, assigning an endpoint by detection requires the threshold from the same absolute-black task. A threshold measured on a nonzero pedestal refers to that pedestal. For the specified 30:1 range in the first paper, the black endpoint remains B/W = 1/30 and the half-response input is 1/√30.

Table 4 | Proxy reading cells from the literature and the step they give.

Cell (source) k Elements Step q Range 1/⁠q
Snellen optotype²⁰, 5′ × 5′, 1′ strokes 2 25 0.040 25
Cell required for N = 30, k = 2: 5.48′ 2 30 0.033 30
Barten asymptotic scale¹⁵˒¹⁷, 15 cycles at 30 c/deg = 30′ 1 30 0.033 30
Cone spacing in the Riccò diameter²¹ 2 17–35 0.029–0.058 17–35
Pure powers fitted to lightness scales³ — — 0.038–0.047 21–26

Several proxy estimates are compatible with a range near 30 under their respective assumptions, without fixing 1/30 as a derived universal threshold. The Snellen optotype, a square letter²⁰ whose strokes are a fifth of its height and which a normal eye reads at 5′, is the smallest cell on which a form is read at acuity 1.0: 25 one-minute elements and a range of 25:1, within a factor of 1.2 of 30; the k = 2 cell required for N = 30, 5.48′, is 10 % larger than the optotype. Barten's model introduces a 15-cycle parameter as an asymptotic upper integration scale rather than a hard window or a measured exact 30 samples (refs 15, 17): at 30 cycles per degree with X₀ = 2° and X_max = 12° its documented effective angular extent is about 29.1′ (approaching 30′, or 30 one-minute elements along one axis, in the asymptotic limit, while read as a two-dimensional area the same scale holds ~900 elements). Cone spacing within the measured complete-summation diameter gives 17–35 elements, a bracket around 30, and 26–35 with natural optics. The pure powers that fit CIE L*, L_r and Munsell best correspond to ranges of 21–26 (ref. 3), near the optotype's 25. Only Barten's asymptotic 15-cycle limit read along one axis reaches 30, and that value scales with its window parameter; the other proxy scales give 17–35 under their own assumptions.

The two readings pull apart. The one estimate that approaches 30, Barten's asymptotic 15-cycle scale taken as 2 × 15 one-minute elements along one axis, is a k = 1 reading, while the exchange rule takes k = 2 for two-dimensional cells; under k = 2, a range of 30 lies inside a band of 25–35, with the 5′ × 5′ optotype giving 25, but is not fixed at 30. A measurement would decide between them: the first step above black on bars that grow in length at a fixed width, against squares that grow in both directions. Under k = 1 the step follows the number of elements along one axis; under k = 2 it follows the area.

The black end inferred under this assumption lies near a thirtieth of white, B ≈ 1/30: 1/30 in the one-axis Barten asymptotic limit (k = 1), and within 1/25–1/35 under k = 2. Read backwards, B = 1/30 needs C/a = 30 along one axis for k = 1, or C/a = √30 ≈ 5.48 across for k = 2; with the 1′ element the required reading cell is 30′ for k = 1 and about 5.5′ for k = 2. The result is consistent with the lightness scale of ref. 3, which sets its black end at B = ρ_B/ρ_W = 0.03/0.90 = 1/30 of white from the reflectances of materials and its middle at σ = 1/√30 (the finer half-step convention 1/60 = 1/(2 · 30) is derived locally below); the 30:1 range of that scale is not used as a premise here. Linking this coded step to the eye's threshold near black needs the independent measurement set out under Predictions.

Origin of 1/60 = 1/(2 · 30)

Visual acuity 1.0 resolves a bar of 1′, a cycle of 2′, so 30 cycles per degree³. Under ideal band-limitation, a signal with no spatial frequency at or above f_max is determined by samples spaced strictly finer than 1/(2 f_max) (sampling strictly above 2 f_max avoids the phase null at the exact endpoint, where a critical-frequency sinusoid can sample to zero at every point; Nyquist–Shannon)²². With f_max = 30 cycles per degree, the limiting interval is

Δx = 1/(2 f_max) = 1/(2 · 30) degree = 1/60 degree = 1′(4)

So 1/60 is the limiting Nyquist interval of the acuity scale, in degrees, and 1′ is the θ₀ of equation (3). It is a spatial interval. The 30 of 30 cycles per degree and the 30 of the range 30:1 are different quantities: the first is a spatial frequency that fixes the element at 1′, the second the number of such elements in the reading cell, and they meet only through the 30′ asymptotic scale of Barten's model read along one axis (Table 4). It becomes the lightness step q₀ = 1/60 only if spatial and lightness sampling are one quantity: with k = 1, a 1° cell holds 60 elements of 1′ along one axis; with k = 2, 60 elements fill an assumed cell of √60′ = 7.75′, a size that needs grounds of its own. A 1° cell along both axes holds 60² = 3,600 Nyquist samples, and with k = 2 would give q₀ = 1/3,600. The lightness reading of the same factor 2 is the half-step error of a uniform quantiser: a step Δ is reconstructed to within ±Δ/2, with a mean squared error near Δ²/12 (ref. 23); for Δ = 1/30 the bound is 1/60 and the RMS error 0.0096. Both readings give 1/(2 · 30), half of a step of 1/30: a spatial interval of 1/60 degree corresponds to the 30 cycles per degree limit, and a lightness step of 1/30 is located to within ±1/60. Neither makes 1/60 a lightness step unless spatial and lightness sampling are one quantity; the step of 1/30 itself is examined conditionally above.

What the argument explains

The middle at σ = 1/√30 follows from the black end: it is the geometric mean of 1/30 and 1. The tier at 1/60 follows as half of a 1/30 step, spatially as the limiting Nyquist interval of 30 cycles per degree and in lightness as the half-step bound of a quantiser of step 1/30. The 30:1 reflectance range of real surfaces, white near 90 % and the darkest common materials near 3 % (ref. 3), is a property of materials; the sampling argument does not explain it, and the closeness of the proxy cell step to the darkest materials is consistent with either a coincidence or an adaptation, which is not tested here. The three coordinates remain distinct: a q_code = 1/30 binary area step over [1/30, 1] is (29/30)/30 ≈ 0.03222 relative to white; ΔV = 1/30 below is a chosen criterion in raw cone response; and ΔL₁ = 0.030 is an OKLab lightness difference at a boundary, about ten times the detection threshold³, which is a different quantity from a luminance ratio of 1/30 and is not explained by this argument.

Limits of the argument

The argument assumes that the black end of a lightness scale is a resolution limit, while the scale defines it as a ratio of reflectances. The first resolvable step above black has not been measured at the optotype scale. The element is taken as 1′ or the cone spacing, and the cell as the optotype, Barten's integration limit or the Riccò diameter; none of these was measured for grey discrimination near black, and the k = 1 and k = 2 readings of Barten's limit differ by a factor of 30. Three measurements would close the gap: the smallest luminance above a dark ground that is told apart from it, on targets of 5′ and of 30′ at photopic adaptation; the summation area for that discrimination; and the same with patterned elements of known size, as in the experiment below.

Sharpness: blur, the pupil and depth of field

Blur sets the element

The element a need not be the diffraction limit. A larger pupil enlarges the blur of any defocus in proportion to its diameter, as with a camera aperture, and the eye's higher-order aberrations grow faster than the diameter, so under the adult optical-aberration model⁴ at zero geometric defocus, higher-order aberrations exceed diffraction above a pupil of about 2.5 mm (about 2.41 mm where the frozen model extrapolates below its 3 mm aberration anchor), and total blur width a grows as adaptation darkens even when geometric defocus is zero; nonzero geometric defocus adds an independent term D_m|ΔF| that exceeds diffraction only once defocus is large enough (for example, at D = 3.023 mm and 555 nm, ΔF = 0.010 D gives 0.1039′ against 0.7700′ diffraction, with crossover near ΔF ≈ 0.0741 D). A change of sharpness is then a change of the element: optical blur changes the resolvable spatial scale, and through equation (2) spatial summation may further change the resolvable lightness step and the number of spatial samples in a cell. The comparison of regular dots, parallel hatching and random dots below is the most direct test. The pupil links the three across the range of adapting luminance: at the dark end a large pupil enlarges aberration blur at zero geometric defocus, giving a coarser step, while also shrinking the depth of field; at the bright end a small pupil gives a deep depth of field, and the sharpness difference between near and far planes shrinks.

The dark end of lightness scales

Joint-model dark-end calculation

For a dark-end scale that joins the pure power at the near-black visual step, use T = q_vis(b) and p = log₃₀4. The scale is v(Y) = Y T^(p−1) for 0 ≤ Y < T and v(Y) = Y^p for Y ≥ T. This is the joint model’s dark-end readout under the specified calibration.

For a numerical comparison, use 1,000 cd/m² adaptation, C = √60′ and b₀ = 1.365′ at zero geometric defocus. Set Q₀ = 0.03106 as a shared model anchor. At 0, 0.125 and 0.25 D, the optical widths are 1.365′, 1.710′ and 2.472′. The visual joins are 0.03106, 0.03776 and 0.05194. The corresponding area-count joins are 0.03106, 0.04875 and 0.10182.

The visual joins reduce the CIE L* RMS residual below Y = 0.1 by 68.6%, 68.0% and 55.8%. The area-count joins give 68.6%, 59.2% and 0.1%. The Munsell reductions are 67.0%, 68.2% and 59.1% for the visual joins, and 67.0%, 62.0% and 8.2% for the area-count joins. These percentages compare model curves with reference scales on the same grid.

The earlier area-count benchmark uses q_code as the junction of the linear dark end. Established lightness scales lie below a pure power Y^0.40759 near black by up to 0.07 (ref. 3). With q from the pupil through the diffraction angle θ (equation (3), q₀ = 1/60), the linear toe removes a third to two fifths of the RMS departure below Y = 0.1 at a central adapting state (θ = 0.77′): 41 % (k = 1) and 32 % (k = 2) for CIE L* (ref. 4). The best single q for CIE L* and Munsell is 0.034–0.038 (ref. 4). At zero geometric defocus, the model gives less diffraction blur and more higher-order aberration blur as the pupil opens. Total blur rises when the increase in aberration blur is larger than the decrease in diffraction blur. A larger pupil also reduces depth of field. With the element taken as the root-sum-square of the diffraction, defocus and aberration widths, adult aberration norms of 0.045–0.327 µm at 3–6 mm, and the cell assumed to be the C = 7.75′ implied by 1/60 at 1′, a cell without independent grounds, setting geometric defocus to zero at moderate luminance (80–2,700 cd/m²) gives q = 0.030–0.045. Under the specified conditions, with geometric defocus set to zero and the reading cell set to 7.75′, the optical-blur model includes diffraction and higher-order aberrations, and a single-join continuous linear toe joined to the pure power law at q_code reduces the root-mean-square residual of CIE L* below Y = 0.1 by 63–69 % (64–68 % for Munsell) at 80–2,700 cd/m². The best-fitting toe of this form reduces the residual by about 69 % for CIE L* and 68 % for Munsell⁴. In the joint model, an increase in total optical blur raises the near-black threshold at fixed adapting background and task. In the earlier area-count calculation, added defocus makes the dark end too dark: at 0.125 D the share removed at the central adapting state falls from 63 % to 32 %, and darker adaptation, the accommodative lag of near viewing (0.25–0.75 D) or the Riccò diameter as the cell give steps beyond the measured scales⁴. At 0.75 D of geometric defocus the central-state blur is 7.97′, above C = 7.75′ and outside the counting model (ref. 4). A second element gives a step near the same value: with the cone spacing as the element and the measured foveal complete-summation diameter as the cell, k = 2 gives the steps of Table 5. The Riccò diameter at the foveal centre was measured at 2.41′ with adaptive-optics correction over a 7.75 mm pupil and retinally stabilised stimuli, and at 2.95′ (2.80–3.25′) with natural optics and a 3 mm pupil, both from increment detection of 550 nm spots shown for 125 ms on a background of about 8 cd/m² (ref. 21). Here the single-join linear toe serves as a first-order approximation; the smooth photopic Barlow dark-light floor of Table 8 (μ_dark/κ = 0.03205 at 200 cd/m²) is the continuous physical floor carried directly into companion Paper 3 (Vela (V-Prism 30)).

Table 5 | Dark-end step q from an element a and the Riccò cell C (k = 2, binary elements).

a (′) C (′) q Removed (%)
0.50ᶜ 2.95ᵃ 0.029 67
0.58ᶜ 2.41ᵇ 0.058 49
0.776ᵈ 2.95ᵃ 0.069 36

Notes: C is a measured diameter of complete spatial summation for spot detection (ref. 21); q = (a/C)²; Removed is the share of the RMS departure of CIE L* below Y = 0.1 that the linear toe at q removes. ᵃ Natural optics, 3 mm pupil; background about 8 cd/m² (8–10 cd/m² in the source's table notes for 3 mm natural-optics rows). ᵇ Adaptive-optics correction over a 7.75 mm pupil, retinal stabilisation; background about 8 cd/m² (the source's 20 cd/m² note belongs to a 6 mm adaptive-optics row). ᶜ Cone spacing. ᵈ Airy angle of a 3 mm pupil at 555 nm. Largest difference left: −0.040, +0.047 and +0.058 in the three rows. For comparison, the diffraction-limited model with q₀ = 1/60 at the central adapting state gives q = 0.0099 (k = 2), removes 32 % and leaves −0.063 (ref. 4).

These scales give a q close to the dark-end fit: the cone-spacing rows bracket the best-fitting q of 0.034–0.038 and remove up to two thirds of the departure for CIE L* (Munsell: 53–65 %). With the Airy angle as the element the step is about twice the best fit. With k = 1 the same three element–cell pairs give q = 0.17–0.26, about four to eight times the best fit. For L_r, which is fitted to CIE L* with a different toe, the cone rows remove 23 % at q = 0.029 and worsen the fit at q = 0.058. The two elements, optical blur in a 7.75′ cell and the cone spacing in the Riccò cell, reach the same step by different calibrations; whether the eye's element is set by the optics or by the cone mosaic remains open, and the Riccò diameter is a summation range for spot detection, not for grey discrimination.

The bright end

With the eye focused on one plane, a plane ΔF dioptres away gains a blur of about D·ΔF beyond the blur of the in-focus plane, which is set by diffraction and the eye's aberrations. Its sharpness difference carries depth while it exceeds the blur-discrimination threshold, a Weber fraction of 0.28–0.56 of the in-focus blur⁴. The smallest depth difference carried by blur is then about 0.13–0.19 D near 130 cd/m² (pupil 2.9 mm). It rises to 0.18–0.27 D at 1 cd/m² as the aberrations of the larger pupil grow, and toward bright adaptation it rises to 0.15–0.23 D at 10⁵ cd/m² as the depth of field deepens, bounded by the 2 mm pupil at 0.16–0.24 D (ref. 4). The threshold is therefore U-shaped along adapting luminance. At the bright end the sharpness difference may vanish only for depth steps of about 0.13–0.24 D, above about 1.2 × 10³–3.6 × 10⁴ cd/m²; larger steps keep it under bright adaptation⁴ (a 0.25 D step is still lost under dim adaptation, ≤ 1.79 cd/m² depending on the Weber fraction, as the larger pupil's aberrations grow). These values rest on adult aberration norms, a Weber model of blur discrimination and a root-sum-square of blur widths, and a linear sum halves the thresholds⁴.

Blur onset and the 1 px sharpness limit

Optical width alone does not make an image look blurred; blur appears when the sampling rate exceeds optical sharpness. When the optical spread b is small enough relative to the sampling interval s, a transition stays within one sample and an edge reads as sharp even though the optics are imperfect; blur becomes visible once spread spills across neighbouring samples or attenuates a one-element pattern below the discrimination step. To evaluate that onset in the same framework, the optical chain starts from pupil diameter D (mm) under the binocular 18-year-old, 60° field (A = 900π deg², λ = 555 nm) Watson–Yellott unified model⁴˒²⁴: f = (L_A A / 846)^0.41, D₀ = 7.75 − 5.75 f / (f + 2), D = D₀ + (y_e − 28.58)(0.021323 − 0.0095623 D₀) with y_e = 19.291 + 44.03 exp(−18 / 4.8441). With K = 10⁻³ · 180 · 60 / π converting mm and radians to arcminutes, the nominal RSS optical width is b(D, ΔF) = √(b_diff(D)² + b_HOA(D)² + b_def(D, ΔF)²), where b_diff = (180 · 60 / π) · 1.22 λ / D (λ in mm), b_HOA = K D · 4√3 · W_RMS / (D / 2)² (adult wavefront RMS W_RMS in µm by log-interpolation), and b_def = K D |ΔF| (ΔF in dioptres; at ΔF = 0 geometric defocus vanishes while diffraction and HOA survive). A 30:1 relative-luminance stimulus Y₀(x) between Y₁ = 1/30 and Y₂ = 1 is convolved with the normalised isotropic 2D Gaussian PSF h(r) = exp(−‖r‖² / (2σ_h²)) / (2πσ_h²) (∫ h = 1, σ_h = κ_PSF b, where κ_PSF = 0.50 for b = 2σ_h and κ_PSF = 1 / (2√(2 ln 2)) ≈ 0.4247 for FWHM), and pooled readout at position u is S(u) = Σ pᵢ V(I(u + xᵢ)) on hexagonal offsets xᵢ with pᵢ = aᵢ / Σ aⱼ (aᵢ = exp(−‖xᵢ‖² / (2σ_w²)) inside cell extent C, or single-cone p₁ = 1 at x₁ = 0). Local cone-level readout applies the cone response of ref. 3 directly, with no inverse mapping:

V(I) = I^n / (I^n + σ_R^n), n = 0.74, σ_R = 1/√30, I(x) = (h * Y₀)(x)(5)

The front-end sharpness stage uses local cone readout without post-receptor pooling (σ_w ≪ s), because Gaussian pooling with σ_w = 0.50′ on the centred hexagonal lattice (s_cone = 0.50′, cone centred at x = 0) already spills across a sharp step at σ_h = 0: assigning white (I = 1) to cones on x = 0 yields a dark shoulder of 0.124, the analytic midpoint σ_h → 0 limit on the same grid yields 0.112, and the continuum Gaussian limit yields 0.088—all more than twice 1/30—whereas the assumed reading cell C = √60′ ≈ 7.75′ governs the lightness-counting step q = (b/C)². Choosing ΔV = 1/30 (0.0333) as a raw cone-response criterion at the 1.0-acuity effective readout scale w = s = 1.0′ (30 cycles per degree) separates three regimes on a 30:1 step edge sampled at x_k = (k + 1/2)s (Table 6). Below blur onset, both off-edge shoulders |V(−1.5s) − V(−0.5s)| and |V(+1.5s) − V(+0.5s)| stay below 1/30 for σ_h/s ≤ 0.2140 (b/s ≤ 0.504 at FWHM; b/s ≤ 0.428 at κ_PSF = 0.50), so the edge reads as a single sharp step. Above onset, the best-phase 1 px sharpness cutoff and bright-side blur onset converge on the same optical width: a 30:1 square-wave grating of bar width w = 1.0′ (30 cycles per degree), sampled at its best phase (bar centres), drops to peak-to-trough modulation |V_max − V_min| = 1/30 at σ_h* = 0.7035′ (σ_h*/w = 0.7035; by contrast, a 0.5′ phase offset places adjacent samples at 0.6835 each and yields zero modulation at this width), while the bright-side step-edge shoulder |V(+1.5′) − V(+0.5′)| at alignment x_k = (k + 1/2)s first rises to 1/30 at σ_h* = 0.7075′ (and the bright-side plateau deviation |V(1) − V(+0.5′)| at 0.6702′). Substituting into q* = (b*/C)² with the assumed cell C = √60′ gives b* = 1.407–1.415′ and q* = 0.0330–0.0334 ≈ 1/30 at κ_PSF = 0.50 (1.340′ and q* = 0.0299 for the plateau deviation), matching the exact q = 1/30 optical point b(D, 0) = √2′ = 1.4142′ (reached in the Watson–Yellott pupil model⁴˒²⁴ at L_A = 396.75 cd/m², D = 2.571 mm and ΔF = 0, with b_diff = 0.9055′ and b_HOA = 1.0863′); at FWHM (κ_PSF = 0.4247) it gives b* = 1.657–1.666′ and q* = 0.0457–0.0463, matching the central in-focus state (1,000 lux grey ground, L_A = 80.53 cd/m², D = 3.023 mm, b = 1.640′, q = 0.0449). Eroding the centre step |V(+s_cone/2) − V(−s_cone/2)| of a 30:1 edge down to 1/30 requires much heavier blur (b* = 4.227′ and q* = 0.298 for anatomical spacing s_cone = 0.50′; b* = 4.904′ and q* = 0.401 for s_cone = 0.58′ at FWHM), which marks near-erasure of the edge rather than blur onset.

Table 6 | Optical-blur vs sampling-rate regime map and best-phase 1 px sharpness cutoff on a 30:1 edge under raw V(I) (s = w = 1.0′, FWHM κ_PSF = 0.4247, chosen ΔV = 1/30).

Blur b (′) q = (b/C)² Centre step Dark shoulder Bright shoulder 1 px grating |ΔV| Regime
0.250 0.0010 0.5575 0.0000 0.0000 0.5575 Sharp single step
0.500 0.0042 0.5245 0.0318 0.0011 0.4956 Sharp–onset boundaryᵃ
1.345 0.0302 0.2192 0.2958 0.0265 0.0782 Asymmetric blur onset (10,000 lux white)
1.414ᵇ 0.0333 0.2078 0.2987 0.0283 0.0655 Exact q = 1/30 optical point (L_A = 397 cd/m²)
1.640ᶜ 0.0449 0.1775 0.2938 0.0329 0.0350 Central in-focus state (1,000 lux grey)
2.000 0.0667 0.1442 0.2607 0.0376 0.0109 Visibly blurred; 1 px grating lost
4.500 0.3375 0.0629ᵈ 0.0960 0.0364 0.0000 Near-erasure of foveal cone step

Notes: C = √60′ = 7.746′; local readout σ_w = 0; chosen raw-response criterion ΔV = 1/30 = 0.0333; edge sampled at x_k = (k + 1/2)s and grating at bar centres (best phase). Centre step = |V(+0.5′) − V(−0.5′)|; dark shoulder = |V(−0.5′) − V(−1.5′)|; bright shoulder = |V(+1.5′) − V(+0.5′)|; 1 px grating = |V_max − V_min| for bar width w = 1.0′ (30 c/deg). ᵃ Dark shoulder reaches 1/30 at b = 0.504′ (σ_h = 0.2140′). ᵇ Exact b(D, 0) = √2′ = 1.4142′ at D = 2.571 mm, L_A = 396.75 cd/m²; at κ_PSF = 0.50, best-phase 1 px grating cutoff is b* = 1.407′ (q* = 0.0330) and bright shoulder onset is b* = 1.415′ (q* = 0.0334). ᶜ Exact central in-focus blur b = 1.6405′ (D = 3.023 mm); at FWHM, best-phase 1 px grating cutoff is b* = 1.657′ (q* = 0.0457) and bright shoulder onset is b* = 1.666′ (q* = 0.0463). ᵈ At anatomical foveal cone spacing s_cone = 0.50′, the centre step |V(+0.25′) − V(−0.25′)| at b = 4.500′ drops to 0.0313 (< 1/30; erasure cutoff b* = 4.227′).

The direct cone response also introduces a strong polarity asymmetry. Because V(1/30) + V(1) = 1 in equation (5), the endpoint slope ratio is V′(1/30)/V′(1) = 30 as an exact identity for endpoint-centred V(I) for any n > 0. Under the specific scenario evaluated here (n = 0.74, Gaussian PSF, alignment x_k = (k + 1/2)s and chosen criterion ΔV = 1/30), the dark-side shoulder crosses 1/30 3.31× earlier than the bright side (σ_h/s = 0.2140 against 0.7075). For an isolated 1.0′ line under the same Gaussian model—comparing the cone response exactly at the line centre x = 0 against the constant surround response |V(I(0)) − V(Y_bg)|—a white line on black stays above 1/30 out to σ_h*/w = 40.96 (FWHM ≈ 96.5′ at w = 1′, a far-field model extrapolation well beyond the in-focus optical range and outside the 0 < b ≤ C counting domain) against 1.727 for a dark line on white (a model-internal scenario ratio of 23.72×; this stays within the model rather than citing an external irradiation measurement). Two independent numerical verification methods confirm the matched crossings (joint-model.py, Fig. 1 and Fig. 2 below): a bar-centre circular-pooling method (Gemini, |S(0) − S(w)|) and a period peak-to-trough square-pooling method (Codex, max S − min S over one grating period); under matched single-cone 30:1 conditions (s = w = 1.0′, ΔV = 1/30) both agree identically on σ_h* = 0.703451756′ for the grating and 0.707542976′ for the bright shoulder, while diverging under pooled cells and phase shifts (full equations and data in joint-model.md). Unlike the endpoint slope identity, both crossing ratios depend on n, PSF shape, stimulus geometry, sampling phase and the chosen ΔV criterion (for example, at n = 0.80 they shift to 3.22× and 23.85×). These correspondences depend on the Gaussian PSF conversion κ_PSF = 0.425–0.50, the assumed cell C = 7.75′ and local cone-level readout (σ_w ≪ s); they represent a conditional model consistency between the chosen ΔV = 1/30 sharpness criterion and the q ≈ 1/30 daylight counting step rather than an empirical measurement of human cone n or a universal threshold.

Fig. 1 | Edge and 1′ grating threshold crossings under raw cone response V(I) (s = 1′, single-cone readout, ΔV = 1/30).

Edge and grating threshold crossings 0.000 0.150 0.300 0.450 0.600 0 0.5 1 1.5 2 Optical Gaussian standard deviation (arcmin) Raw V difference
  • Dark shoulder
  • Bright shoulder
  • Grating, 1 arcmin bar
  • Criterion, 1/30

Fig. 2 | Grating readout across phase shifts at σ_h = 0.30′ comparing single-cone, circular (Gemini) and square (Codex) pooling (σ_w = 1.00′).

Grating phase and readout geometry 0.000 0.150 0.300 0.450 0.600 0 0.25 0.5 0.75 1 Readout phase as a fraction of bar width Raw V difference Pooled traces on an expanded scale 0.0000 0.0008 0.0016 0.0024 0 0.25 0.5 0.75 1 Readout phase as a fraction of bar width Raw V difference
  • Single cone, 0.50 arcmin bar
  • Single cone, 1.00 arcmin bar
  • Circle pooling, 1.00 arcmin bar
  • Square pooling, 1.00 arcmin bar

Spatial weights, noise and visual discrimination

Equation (2) gives q_code = 1/N for N equally weighted binary elements. The joint model describes q_vis with the cone response, spatial weights and the variance of the comparison between intervals. The adopted visual law fixes the relative scaling of the threshold with optical blur. The readout in equations (5)–(8) supplies the response gain and noise decomposition needed to interpret that scaling at a specified pedestal.

Spatial weights and effective sample count

Three empirical paradigms constrain how the human fovea and primate retina weight cones across space. First, adaptive-optics increment detection measures complete spatial summation (Riccò's area) at the foveal centre with a reported mean area of 4.65 arcmin² across observers (and mean equivalent diameter d = 2.41′, whose exact circular area is 4.56 arcmin²), encompassing 17–37 cones across individual cone maps (including 23 for one observer); task-specific Gaussian pooling fits yield a space constant of σ_w = 1.6′ under adaptive optics, 1.8′ under natural optics and 1.7′ in a joint fit²¹. On a centred ideal two-dimensional hexagonal foveal lattice (cone area A_cone = (√3/2)s_cone²), a d = 2.41′ circle holds 37 cones at s_cone = 0.40′, 19 at 0.50′ and 19 at 0.58′ (continuum counts 32.9, 21.1 and 15.7), overlapping the empirical 17–37 range. Second, psychophysical classification-image templates for foveal detection and position discrimination recover localised spatial weighting profiles closely aligned with linear-filter expectations (template–signal correlations r = 0.7–0.8), showing that observers weight spatial regions non-uniformly rather than as a flat boxcar²⁵. Third, multi-electrode reverse correlation at single-cone resolution in macaque retina maps non-uniform cone weights onto individual retinal ganglion cells, demonstrating spatially structured synaptic weighting already at the retinal output²⁶.

For any normalised spatial weight vector w = (w₁, …, w_N) with Σᵢ wᵢ = 1, the deterministic binary coding step remains q_code = 1/N if all N elements are counted equally, whereas the variance of independent identically distributed cone noise scales with Σᵢ wᵢ². The effective sample count for independent noise averaging is therefore N_eff = 1 / Σᵢ wᵢ², so the noise standard deviation shrinks only by 1/√N_eff, not by 1/N. For a two-dimensional Gaussian weight profile wᵢ ∝ exp(−rᵢ²/(2σ_w²)) truncated to the circular reading cell of radius R_C = C/2 = √60′/2 = 3.873′, the continuum approximation gives N_eff,unb = 4πσ_w² / ((√3/2)s_cone²) for an unbounded Gaussian and N_eff = N_eff,unb · tanh(R_C² / (4σ_w²)) when truncated at R_C (Table 7). At Tuten's joint foveal pooling scale σ_w = 1.7′ inside R_C = 3.873′, N_eff = 142.7 cones at s_cone = 0.50′ (107.8 at 0.58′), giving a noise-compression factor 1/√N_eff = 0.0837 (0.0963 at 0.58′)—a dimensionless scaling-factor ratio of 17.7× relative to the equal-weight single-cone coding step 1/N = 0.00474 at s_cone = 0.50′ (and 15.7× relative to 1/N = 0.00613 at s_cone = 0.58′). Importantly, Riccò's area relation A · ΔL_th(A) = const constrains chiefly the overall pooling scale σ_w; separating interior pooling from edge-driven readout requires spatially targeted centre, edge and surround perturbations on a fixed patch.

Table 7 | Effective sample count N_eff and noise compression 1/√N_eff vs q_code = 1/N on the 2D hexagonal foveal cone lattice (R_C = 3.873′).

Cone spacing s_cone (′) Pooling σ_w (′) N_eff (truncated) N_eff (continuum) N_eff (unbounded) 1/N_eff 1/√N_eff Peak w_max
0.50 (N = 211, 1/N = 0.00474) 0.5 14.51 14.51 14.51 0.06892 0.2625 0.1378
0.50 1.0 57.96 57.98 58.04 0.01725 0.1313 0.0345
0.50 1.6 132.23 133.52 148.59 0.00756 0.0870 0.0143
0.50 1.7 142.72 144.44 167.74 0.00701 0.0837 0.0130
0.50 1.8 152.06 154.24 188.05 0.00658 0.0811 0.0119
0.50 2.0 167.35 170.43 232.17 0.00598 0.0773 0.0103
0.50 ∞ (equal) 211.00 217.66 ∞ 0.00474 0.0688 0.0047
0.58 (N = 163, 1/N = 0.00613) 0.5 10.78 10.78 10.78 0.09277 0.3046 0.1855
0.58 1.0 43.09 43.09 43.13 0.02321 0.1523 0.0464
0.58 1.6 99.56 99.23 110.42 0.01004 0.1002 0.0191
0.58 1.7 107.78 107.34 124.66 0.00928 0.0963 0.0173
0.58 1.8 115.16 114.63 139.76 0.00868 0.0932 0.0158
0.58 2.0 127.36 126.65 172.54 0.00785 0.0886 0.0136
0.58 ∞ (equal) 163.00 161.75 ∞ 0.00613 0.0783 0.0061

Notes: Discrete hexagonal lattice truncated inside R_C = √60′/2 = 3.8730′; continuum formula N_eff = [4πσ_w²/((√3/2)s_cone²)] tanh(R_C²/(4σ_w²)). Equal-weight coding step q_code = 1/N; independent noise SD scales as 1/√N_eff.

Noise sources and photopic calibration

Visual discrimination is represented here by four successive modelled noise layers, each anchored by physiological or psychophysical measurements:

1.

Photon shot noise. Absorbed photons in cone i follow a Poisson count Nᵢ ~ Poisson(μᵢ) with mean and variance μᵢ = κᵢ Iᵢ, where κᵢ = μ_white is the mean isomerisation count per cone per presentation at reference white (I = 1). Ideal-observer models propagating optics and Poisson cone absorptions set the physical sensitivity ceiling²⁷⁻²⁹.

2.

Single-cone intrinsic noise (modelled surrogate). Macaque cone recordings identify cGMP concentration fluctuations and channel gating as major sources of physiological variability, rather than spontaneous pigment activation alone. In darkness, spontaneous pigment activation could account for at most about 10 % of total foveal current variance; at a background of 5,000 R*/s, the lowest-frequency component accounted for about 30 % of total current variance, an upper bound on the combined contribution of spontaneous and light-driven pigment activation³⁰. For current noise measured in the 1–10 Hz band, the original calibration gave an input-equivalent dark-light rate of 620 R*/s per cone (95 % CI 480–835 R*/s; carried below as a sensitivity envelope). A later calibration corrected the half-desensitising background only, from 4,500 to 2,250 R*/s³¹. Here μ_dark = 620 T (together with its Poisson, zero-clipped and shifted-pedestal implementations) is used as a task modelling surrogate for input-equivalent variance over a window T; converting to a specific human readout requires its temporal filter and current-noise spectrum.

3.

Correlated retinal noise. Paired recordings in peripheral macaque retina (> 20°, ~4,000 R* cone⁻¹ s⁻¹) show that shared cone inputs drive positive noise correlations among same-sign retinal ganglion cells and negative correlations between ON and OFF cells, limiting how much spatial pooling can suppress noise³². Direct measurements of pairwise correlation ρ in the central human fovea are not yet available, so ρ ∈ {0.05, 0.10, 0.20} is treated as a sensitivity parameter below.

4.

Downstream and decision noise. External-noise masking separates equivalent input noise N_eq from sampling efficiency η via E_th = (N_ext + N_eq)/η (ref. 33), and double-pass consistency separates reproducible stimulus-locked error from internal decision noise³⁴; modern hierarchical analyses confirm that both early receptor noise and late decision noise shape psychophysical thresholds³⁵. Compared with a photon-ideal observer, human grating thresholds sit ~20× higher in classical analyses²⁷, while computational-observer simulations incorporating realistic optics, photocurrent encoding, fixational eye movements and non-ideal readout narrow the initial 5–10× retinal gap to ~1–2× relative to human behaviour²⁸˒²⁹. For uniform patches near black, increment–decrement discrimination follows Weber-like scaling ΔW/W = const for durations above 100 ms³⁶, and luminance pedestals reveal asymmetric ON/OFF sensitivity near low contrast³⁷.

To evaluate the modelled balance between photon shot noise and the input-equivalent macaque dark-light surrogate on realistic displays and prints, κ = μ_white is calibrated from the Watson–Yellott unified pupil formula²⁴ (18-year-old, binocular, 60° field, as in ref. 4) with a baseline photopic conversion factor c_td = 12 R* cone⁻¹ s⁻¹ td⁻¹ (sensitivity band 8–16 R* cone⁻¹ s⁻¹ td⁻¹, within an illustrative 8–20 R* cone⁻¹ s⁻¹ td⁻¹ photopic band that depends on spectral power distribution, ocular transmittance, cone aperture and Stiles–Crawford apodisation²⁷˒²⁸), giving κ = c_td · L_white · (πD²/4) · T with geometric pupil area and μ_black = κ/30 at the 30:1 black end (Table 8). Conditionally on both mean photon capture μ_black and the input-equivalent dark variance surrogate μ_dark scaling linearly with integration duration T, the ratio μ_dark/μ_black is invariant to T and depends only on display white luminance L_white and adapting surround L_A. Under c_td = 12 and a quarter-white surround (L_A = 0.25 L_white), exact dark-to-shot equality (μ_dark/μ_black = 1) occurs at L_white = 189.8 cd/m²: intrinsic dark noise dominates black-end shot noise at 80 cd/m² (ratio 1.89), sits near 1:1 balance at 200 cd/m² (ratio 0.96, with μ_black = 80.6 and μ_dark = 77.5 R* at 125 ms), and falls below shot noise at 400 cd/m² (ratio 0.57). On a full-white surround (L_A = L_white), pupil constriction reduces retinal illuminance and shifts exact dark-to-shot equality upward by 48 % to L_white = 280.9 cd/m² (ratios 2.70, 1.32 and 0.75 at 80, 200 and 400 cd/m²). For comparison, the independent square-tile control below uses the upper end of the illustrative photopic band (c_td = 20 R* cone⁻¹ s⁻¹ td⁻¹), T = 200 ms and a Stiles–Crawford effective pupil area (6.96 mm²), giving κ = 5,568 R*—2.3× above the Table 8 baseline (κ = 2,418 R* at 200 cd/m², 125 ms), which lowers pure shot SD by √2.3 ≈ 1.52× at fixed normalised intensity and reinforces that independent photon noise alone lies far below 1/30.

Table 8 | Photopic cone isomerisation calibration κ = μ_white, μ_black = κ/30 and dark-to-black noise ratio μ_dark/μ_black (c_td = 12 R* cone⁻¹ s⁻¹ td⁻¹, macaque 1–10 Hz dark-light surrogate 620 R*/s).

L_white (cd/m²) L_A (cd/m²) Pupil D (mm) White (td) T (ms) κ = μ_white (R*) [c = 8–16] μ_black (R*) μ_dark (R*) μ_dark/μ_black Regime at I = 1/30
80 20 3.614 820.5 125 1,231 [821–1,641] 41.0 77.5 1.89 Dark > shot
80 20 3.614 820.5 200 1,969 [1,313–2,626] 65.6 124.0 1.89 Dark > shot
80 20 3.614 820.5 500 4,923 [3,282–6,564] 164.1 310.0 1.89 Dark > shot
80 80 3.025 575.1 125 863 [575–1,150] 28.8 77.5 2.70 Dark > shot
200 50 3.203 1,611.9 125 2,418 [1,612–3,224] 80.6 77.5 0.96 Near 1:1 (exact 189.8 cd/m²)
200 50 3.203 1,611.9 200 3,869 [2,579–5,158] 129.0 124.0 0.96 Near 1:1 (exact 189.8 cd/m²)
200 50 3.203 1,611.9 500 9,671 [6,448–12,895] 322.4 310.0 0.96 Near 1:1 (exact 189.8 cd/m²)
200 200 2.738 1,177.9 125 1,767 [1,178–2,356] 58.9 77.5 1.32 Dark > shot (1:1 at 280.9 cd/m²)
400 100 2.948 2,730.8 125 4,096 [2,731–5,462] 136.5 77.5 0.57 Shot > dark
400 100 2.948 2,730.8 200 6,554 [4,369–8,739] 218.5 124.0 0.57 Shot > dark
400 100 2.948 2,730.8 500 16,385 [10,923–21,846] 546.2 310.0 0.57 Shot > dark
400 400 2.569 2,073.3 125 3,110 [2,073–4,147] 103.7 77.5 0.75 Shot > dark

Notes: Pupil diameter D from the Watson–Yellott unified formula (18 y, binocular, 60° field)⁴˒²⁴ with geometric pupil area and baseline c_td = 12 R* cone⁻¹ s⁻¹ td⁻¹ (sensitivity band 8–16, within an illustrative 8–20 R* cone⁻¹ s⁻¹ td⁻¹ photopic band depending on spectrum, cone aperture and Stiles–Crawford apodisation²⁷˒²⁸). Quarter-white (L_A = 0.25 L_white) and full-white (L_A = L_white) surrounds reach exact μ_dark/μ_black = 1 at L_white = 189.8 and 280.9 cd/m², respectively. The 95 % CI sensitivity envelope on the 1–10 Hz macaque dark-light surrogate (480–835 R*/s; ref. 30) gives 60.0–104.4 R* at 125 ms, 96.0–167.0 R* at 200 ms and 240.0–417.5 R* at 500 ms. Invariance of μ_dark/μ_black to T holds conditionally on both mean capture and equivalent dark variance scaling linearly with T. The independent square-tile control (Methods) uses c_td = 20, T = 200 ms and Stiles–Crawford effective pupil area (6.96 mm²), giving κ = 5,568 R* (2.3× the 200 cd/m², 125 ms baseline; pure shot SD √2.3 ≈ 1.52× lower).

Minimal joint readout model and identifiability

To test how spatial weights and noise determine modelled visual discrimination between two stimuli (j = 0, 1) presented in an unbiased two-interval forced-choice (2IFC) task, each cone i receives blurred relative luminance Iᵢⱼ = (h * Yⱼ)(xᵢ), passes it through the raw cone response V(I) of equation (5), and contributes with spatial weight wᵢ (Σᵢ wᵢ = 1) to a pooled decision variable Rⱼ = Σᵢ wᵢ V(Ĩᵢⱼ). For independent intervals, let Σ₀ and Σ₁ denote the cone-response covariances and σ_d² the variance of independent noise added to the interval difference. With Gaussian comparison noise and a noiseless approximation to the mean response,

ΔR = Σᵢ wᵢ [V(Iᵢ₁) − V(Iᵢ₀)], S_D² = wᵀ(Σ₀ + Σ₁)w + σ_d², P_correct = Φ(|ΔR|/S_D)(6)

where Φ is the standard normal cumulative distribution function (if cross-interval noise is correlated with covariance Σ₀₁, the variance term gains −wᵀ(Σ₀₁ + Σ₁₀)w), reported comparison sensitivity is defined as d′ = |ΔR|/S_D (using the two-interval difference standard deviation S_D; if a single-interval convention uses only receptor variance v while S_D² = 2v + σ_d², then d′_single / d′_reported = √(2 + σ_d²/v), reducing to √2 only when σ_d² = 0, or equivalently when half of σ_d² is assigned to each interval), and 75 % correct occurs at |ΔR| = Φ⁻¹(0.75) S_D = 0.6745 S_D. To first order around the cone operating luminances Iᵢⱼ, let τᵢⱼ² = V′(Iᵢⱼ)²(μᵢⱼ + μ_dark)/κᵢ² denote the total marginal receptor variance of cone i (combining shot and intrinsic dark variance); the receptor covariance decomposes into diagonal shot variance, diagonal intrinsic cone dark variance and off-diagonal shared covariance ((Σ_shared,j)ᵢᵢ = 0, so diagonal receptor variance is never counted twice):

Σⱼ ≃ diagᵢ[V′(Iᵢⱼ)² μᵢⱼ/κᵢ²] + Σ_cone,j + Σ_shared,j, V′(I) = n σ_R^n I^(n−1) / (I^n + σ_R^n)²(7)

Equation (7) exposes a fundamental mathematical asymmetry near I → 0⁺ for the unshifted first-order approximation with 1/2 < n < 1 (here n = 0.74). Because V′(I) ∝ I^(n−1) = I^(−0.26) diverges as I → 0⁺, pure photon shot variance V′(I)² (I/κ) scales as I^(2n−1) = I^(+0.48) → 0 and therefore has no analytical pole at I → 0⁺, whereas first-order propagated intrinsic dark variance V′(I)² (μ_dark/κ²) scales as I^(2n−2) = I^(−0.52) → +∞. Even for pure shot noise, however, first-order linearization breaks down in the discrete sub-single-photon regime (μ ≲ 1): at I = 10⁻⁶ (μ ≪ 1), first-order propagation overpredicts the exact discrete Poisson shot standard deviation by 2.87× under the κ = 5,568 R* square-tile calibration (verified in paper-spatial-weights-noise-independent-20261125.csv, and 3.59× under the Table 8/9 κ = 2,418 R* calibration), so exact Poisson summation or sampling is required whenever μ ≲ 1. Direct Poisson Monte Carlo sampling (20,000 single-cone draws per pedestal and 5,000 full 211-cone lattice trials) illustrates this breakdown at 80 cd/m² and 125 ms: at the sampled pedestals I₀ ∈ {0.01, 1/30, 0.1826, 0.90}, first-order linearization at I₀ agrees with zero-clipped Poisson sampling to within 3 % (MC/first-order ratio 0.983 at 0.01 and 1.029 at 1/30), although intermediate operating points can exceed 3 % (for example, exact first-order/clipped SD ratio 0.937 at I₀ = 0.0172), and below 0.01 first-order linearization overpredicts the clipped standard deviation by 1.29× at I₀ = 0.005, 1.87× at I₀ = 0.002 and 3.02× at I₀ = 0.0005 (1.88× on the full 211-cone lattice at I₀ = 0.002; at 200 cd/m², 125 ms and I₀ = 0.002, exact clipped moments lower the pooled Gaussian model response threshold from 0.00359 to 0.00260). Evaluating V(I) at the Barlow additive dark-light operating point³⁸ I_eff = I₀ + μ_dark/κ removes the I → 0⁺ singularity altogether: first-order propagation at I_eff agrees with direct Poisson Monte Carlo to about 1.2 % across the sampled pedestals I₀ ∈ [0.0005, 0.90] (maximum deviation 1.22 %; single-cone ratios 0.988–1.008; full 211-cone lattice ratios 1.002–1.011).

Let ΔY = ΔL/L_white be the white-normalised luminance increment, so Iᵢ₁ = Iᵢ₀ + bᵢ ΔY for spatial profile bᵢ. Linearising around Iᵢ₀ gives the 75 % threshold in relative units. The physical threshold is ΔL_75 = L_white ΔY_75.

ΔY_75 ≃ 0.6745 S_D / |Σᵢ wᵢ V′(Iᵢ₀) bᵢ|(8)

Equation (8) clarifies both the scaling of modelled visual discrimination and its identifiability boundary. First, whereas the deterministic equal-weight coding step scales as q_code = 1/N, the independent-noise threshold scales as S_D ∝ 1/√N_eff; with pairwise equicorrelation ρ across receptor marginal standard deviations τᵢ, the total receptor variance per interval is wᵀ Σ_tot,j w = (1 − ρ) Σᵢ (wᵢ τᵢ)² + ρ (Σᵢ wᵢ τᵢ)², which for uniform marginal SD τ reduces to τ²[(1 − ρ)/N_eff + ρ] and adds a floor ρ τ² that does not shrink to zero even as N_eff → ∞. Second, a single scalar discrimination threshold fixes only the signal-to-noise ratio |ΔR|/S_D: it cannot separate spatial weights wᵢ from early receptor variance, shared correlation ρ or late decision noise σ_d². External-noise masking and double-pass repeats constrain components, while separating early, shared and late noise uniquely requires a specified covariance and response model tested with independently varied spatial, luminance and noise perturbations together with an explicit identifiability check.

Visual threshold in the three-study model

The third study gives the equilateral cross-section ratio k_vis = √3/2 ≈ 0.866025, which we retain as a pre-specified candidate near-black visual exponent; the link from cross-section ratio to visual-threshold exponent is tested by experiment. The pedestal, adaptation, stimulus geometry, reading-cell size C and blur convention are fixed. Let G(b) be the absolute pooled derivative with respect to ΔY in equation (8). Let z₇₅ = Φ⁻¹(0.75). In the linearised model the joint law gives:

q_vis(b) = z₇₅ S_D(b) / G(b) = Q₀ (b/b₀)^k_vis q_vis(b) / Q₀ = [q_code(b) / q_code(b₀)]^(k_vis/2) S_D(b) / G(b) = (Q₀/z₇₅)(b/b₀)^k_vis

Use the same-task threshold at reference blur b₀ for Q₀. A model-only calculation can anchor Q₀ to equation (8) at b₀. At b/b₀ equal to 0.5, 1 and 2, the candidate visual threshold ratios are 0.549, 1 and 1.823, against 0.5, 1 and 2 for a linear model (k = 1) and 0.250, 1 and 4 for area counting (k = 2).

The last equality constrains the net noise-to-gain ratio across blur widths in the domain 0 < b ≤ C. It identifies a ratio. To attribute the change to spatial weights, receptor noise or decision noise, use the separate perturbations described in the readout experiment.

Table 9 evaluates linearised finite-response thresholds from equations (6)–(7) on the 211-cone foveal lattice (s_cone = 0.50′, R_C = 3.873′, Tuten σ_w = 1.7′, N_eff = 142.7) across pedestals from I₀ = 0.002 to 0.90 and three display conditions. At the 30:1 black end (I₀ = 1/30) under 200 cd/m² and 125 ms, independent photon shot noise alone yields |ΔR_75| = 0.00113 (Weber fraction ΔI_75/I₀ = 0.89 %), adding the 620 R*/s macaque 1–10 Hz dark-light surrogate raises |ΔR_75| to 0.00158 (1.25 %; 95 % CI envelope 0.00150–0.00171 for 480–835 R*/s; additive dark-light operating point 0.00102 with identical Weber fraction 1.25 %), and 1–2 % intraocular veiling glare raises the Weber fraction modestly to 1.34–1.43 % (while hitting I₀ = 0.002 much harder, raising ΔI_75/I₀ from 15.0 % to 17.1–18.9 %). Shared cone correlation has a far larger effect because it defeats √N_eff averaging: ρ = 0.05, 0.10 and 0.20 lift |ΔR_75| at I₀ = 1/30 to 0.00449, 0.00614 and 0.00851 (2.8×, 3.9× and 5.4× the independent shot-plus-dark value, respectively). Comparing these baseline thresholds against an illustrative response benchmark |ΔR_75| = 1/30 gives a response-threshold ratio (1/30)/|ΔR_75| of 21.0× at 200 cd/m² (12.4× at 80 cd/m² and 38.7× at 400 cd/m²), corresponding under fixed operating-point variance to an additive decision standard deviation σ_d ≈ 0.0494 (re-evaluating receptor covariance at the larger target interval shifts 21.03× to 21.86× at I₀ = 1/30, 200 cd/m², 125 ms; at I₀ = 0.90, the maximum upward response change within [0, 1] is 0.0137 < 1/30, so reaching +1/30 would exceed reference white at I₁ = 1.172).

Table 9 | Linearised 75 % 2IFC discrimination thresholds (|ΔR_75| and Weber fraction ΔI_75/I₀) across pedestals and modelled noise layers (s_cone = 0.50′, σ_w = 1.7′, N_eff = 142.7).

Condition & pedestal I₀ (a) Shot |ΔR_75| (b) +Dark |ΔR_75| (ΔI/I₀) (c) ρ = 0.05 / 0.10 / 0.20 |ΔR_75| (d) Glare 1 % / 2 % ΔI/I₀ (e) Ratio (1/30)/|ΔR_75| (fixed-op σ_d)
200 cd/m², 125 ms · I₀ = 0.002 0.00089 0.00359 (0.1503) 0.00993 / 0.01342 / 0.01834 0.1707 / 0.1891 9.3× (0.0491)
200 cd/m², 125 ms · I₀ = 0.010 0.00112 0.00229 (0.0334) 0.00646 / 0.00881 / 0.01218 0.0371 / 0.0405 14.5× (0.0493)
200 cd/m², 125 ms · I₀ = 1/30ᵃ 0.00113 0.00158 (0.0125) 0.00449 / 0.00614 / 0.00851 0.0134 / 0.0143 21.0× (0.0494)ᵈ
200 cd/m², 125 ms · I₀ = 0.1826 0.00070 0.00076 (0.0041) 0.00216 / 0.00296 / 0.00410 0.0042 / 0.0043 43.8× (0.0494)
200 cd/m², 125 ms · I₀ = 0.900 0.00023 0.00023 (0.0017) 0.00066 / 0.00090 / 0.00125 0.0018 / 0.0018 144.0× (0.0494)ᵉ
80 cd/m², 125 ms · I₀ = 1/30ᵇ 0.00159 0.00269 (0.0212) 0.00759 / 0.01035 / 0.01431 0.0223 / 0.0233 12.4× (0.0493)
400 cd/m², 200 ms · I₀ = 1/30ᶜ 0.00069 0.00086 (0.0068) 0.00245 / 0.00335 / 0.00465 0.0074 / 0.0080 38.7× (0.0494)

Notes: All rows are linearised receptor-covariance model evaluations at L_A = 0.25 L_white on the 211-cone hexagonal lattice inside R_C = 3.873′. Columns: (a) Poisson shot noise only; (b) shot + 620 R*/s macaque 1–10 Hz dark-light surrogate; (c) total equicorrelated receptor variance with pairwise correlation ρ; (d) 1 % and 2 % additive veiling glare (fraction of L_white) on top of shot + dark; (e) response-threshold ratio (1/30)/|ΔR_75| relative to column (b) and fixed-operating-point σ_d approximation placing |ΔR_75| at 1/30. ᵃ 95 % CI envelope on the dark-light surrogate (480–835 R*/s) gives |ΔR_75| = 0.00150–0.00171 (ΔI/I₀ = 0.0118–0.0135); additive dark-light operating point gives |ΔR_75| = 0.00102 (ΔI/I₀ = 0.0125). ᵇ Dark-light 95 % CI envelope: 0.00248–0.00298 (ΔI/I₀ = 0.0196–0.0235); additive dark-light: 0.00128 (ΔI/I₀ = 0.0212). ᶜ Dark-light 95 % CI envelope: 0.00083–0.00091 (ΔI/I₀ = 0.0065–0.0072); additive dark-light: 0.00065 (ΔI/I₀ = 0.0068). ᵈ Re-evaluating receptor covariance at the finite target interval shifts the multiplier from 21.03× to 21.86×. ᵉ Infeasible upward target within [0, 1]: maximum upward ΔR from I₀ = 0.900 to white (1.0) is 0.0137 < 1/30 (reaching +1/30 requires I₁ = 1.172).

End-to-end halftone step visibility

The joint model predicts numerically whether flipping a single binary halftone unit corresponding to one coded step q_code = 1/30 is detectable after optical blur, the discrete foveal cone mosaic, the nonlinear cone response V(I), spatial weighting and modelled stochastic noise. Taking the reading cell C = √60′ = 7.746′ (R_C = 3.873′, 211 cones at s_cone = 0.50′), one coded step q_code = (b/C)² = 1/30 corresponds to a unit disk of diameter b = √2′ = 1.4142′ (radius 0.7071′). Two stimuli differing by one flipped white unit disk centred at (r, 0) (either centred at r = 0′ or off-centre at r = 2.5′) are convolved in two dimensions with the optical Gaussian PSF at both FWHM (σ_h = 0.4247 b = 0.601′) and half-diameter (σ_h = 0.50 b = 0.707′) under 200 cd/m² (L_A = 50 cd/m², T = 125 ms, κ = 2,418 R*, μ_dark = 77.5 R*), across three backgrounds: (1) all-black (I₀ = 1/30), (2) a two-dimensional mid-grey binary halftone array (white disks of diameter √2′ on a hexagonal grid of pitch d_ht = 3.428′, periodic target coverage f = 0.1544 matching unlimited mean luminance 1/√30 = 0.1826, with triangular lattice basis vectors (p, 0) and (p/2, √3 p / 2) whose first axis is parallel to the flip axis, aperture centred on the cone-field origin, lattice origin offset (1.25, 1.50)′ and field truncated at radius R_C + 4′; the independent converged calculation yields finite 211-cone sampled means of 0.1745 at σ_h = 0.601′ and 0.1767 at σ_h = 0.707′, compared with 0.174680 / 0.176811 from 60-panel quadrature and 0.174580 / 0.176720 from 120-panel quadrature), and (3) a uniform mid-grey reference (I₀ = 1/√30). Because the mid-grey halftone dot phase is a material geometric input—an alternative zero-offset grid with the centre background disk removed for the test flip shifts centred FWHM Gaussian ΔR from 0.0641 to 0.1177—Table 10 tests fixed-geometry visibility under labelled numerical branches and is distinct from the truly equal-mean square-tile control below.

Table 10 | End-to-end modelled visibility of a single flipped binary halftone unit (b = √2′, q_code = 1/30; 200 cd/m², 125 ms, s_cone = 0.50′).

Background & flip site Weights PSF σ_h (′) ΔR S_D (ρ = 0) d′ (1×) d′ (5×) d′ (10×) S_D (ρ = 0.10) d′ (ρ = 0.10, 5×) P_correct (ρ = 0.10, 5×)
All-black, r = 0′ Tuten 1.7′ 0.601 0.1228 0.00204 60.3 12.06 6.03 0.00817 3.01 99.9 %
All-black, r = 0′ Equal 0.601 0.0557 0.00186 30.0 6.00 3.00 0.00862 1.29 90.2 %
All-black, r = 2.5′ Tuten 1.7′ 0.601 0.0510 0.00227 22.4 4.49 2.24 0.00874 1.17 87.8 %
All-black, r = 2.5′ Equal 0.601 0.0523 0.00186 28.0 5.61 2.80 0.00865 1.21 88.7 %
Mid-grey halftone, r = 0′ Tuten 1.7′ 0.601 0.0641 0.00120 53.4 10.68 5.34 0.00461 2.78 99.7 %
Mid-grey halftone, r = 0′ Equal 0.601 0.0280 0.00109 25.6 5.12 2.56 0.00489 1.14 87.4 %
Mid-grey halftone, r = 2.5′ Tuten 1.7′ 0.601 0.0264 0.00132 20.0 4.00 2.00 0.00487 1.09 86.1 %
Mid-grey halftone, r = 2.5′ Equal 0.601 0.0267 0.00110 24.4 4.87 2.44 0.00490 1.09 86.2 %
Uniform mid-grey, r = 0′ Tuten 1.7′ 0.601 0.0440 0.00103 42.6 8.51 4.26 0.00413 2.13 98.4 %
Uniform mid-grey, r = 0′ Equal 0.601 0.0194 0.00091 21.3 4.27 2.13 0.00424 0.91 81.9 %
Uniform mid-grey, r = 2.5′ Tuten 1.7′ 0.601 0.0178 0.00111 16.1 3.21 1.61 0.00429 0.83 79.7 %
Uniform mid-grey, r = 2.5′ Equal 0.601 0.0185 0.00091 20.4 4.07 2.04 0.00425 0.87 80.8 %
All-black, r = 2.5′ Tuten 1.7′ 0.707 0.0561 0.00226 24.9 4.97 2.49 0.00869 1.29 90.2 %
Mid-grey halftone, r = 2.5′ Tuten 1.7′ 0.707 0.0253 0.00122 20.7 4.14 2.07 0.00458 1.10 86.5 %
Uniform mid-grey, r = 2.5′ Tuten 1.7′ 0.707 0.0189 0.00111 17.1 3.41 1.71 0.00428 0.88 81.1 %

Notes: All 211 cones inside R_C = 3.873′ evaluated by numerical quadrature (n = 60 panels, cross-checked at n = 120) of the 2D Gaussian-convolved disk PSF, raw V(I), and first-order receptor variance propagation in equations (6)–(7) with shot + 620 R*/s macaque 1–10 Hz dark-light surrogate (d′ = |ΔR|/S_D). First-order receptor SD is checked against direct Poisson Monte Carlo at 80 and 400 cd/m² and against exact Poisson moments at 200 cd/m², 125 ms across 1,357 simulated inputs with I ≥ 1/30 (first-order/exact clipped SD ratios 0.992–0.999). In the Uniform mid-grey reference, replacing a mid-grey disk (1/√30) with white (1) applies a luminance increment of 1 − 1/√30 = 0.8174 (84.6 % of the full black-to-white binary flip 29/30 = 0.9667). For Uniform mid-grey at r = 2.5′, σ_h = 0.707′, converged disc integration gives ideal d′ = 17.04 (rounding to 17.0 vs 17.1 at 60 panels). Ideal 1× assumes no post-receptoral inefficiency; the 5× and 10× sensitivity settings multiply the modelled noise SD. Grating studies give context for these settings²⁸˒²⁹. Full HalfDiam (σ_h = 0.707′) table for r = 0′ and equal weights is in paper-spatial-weights-noise-20261125.csv (P_correct = 99.9 % all-black centered, 99.7 % mid-grey halftone centered, 98.6 % uniform mid-grey centered, 81.7–92.6 % off-centre or equal-weighted).

The independent-receptor version of Table 10 gives model comparison signal-to-noise ratios d′ = |ΔR|/S_D of 16.1–60.3 at FWHM and 17.0–64.7 (17.1 at 60 panels) at σ_h = 0.707′ for one q_code = 1/30 unit. Under equal weights on the all-dark background, widening the blur between the two modelled PSFs increased ΔR from 0.0557 to 0.0619. This is consistent with the concavity of V(I) in this model as a bright increment is spread over more dark cones. With assumed correlation ρ = 0.10 and a 5× noise multiplier, the selected off-centre or equal-weight flips give approximately 80–90 % correct at FWHM (79.7–90.2 %, reaching 92.6 % under the broader σ_h = 0.707′ PSF), and Gaussian-centred flips give about 98–99.9 %. These are conditional model predictions for the tested flip locations. Human same-task thresholds and the distribution of flip locations would be needed to estimate visibility across the cell. An independent simulation flipped one square tile of side √2′ in a 5 × 6 dark array. Each flip increased the array mean by 1/30 of the black-to-white luminance range. The pooled responses differed from the all-dark array by 0.119 near the centre, 0.0355 at the side and 0.00616 at the corner. With an assumed comparison-noise standard deviation of 0.01 in normalised response units, the model's two-interval forced-choice correct rates were approximately 100 %, 99.98 % and 73.0 %, respectively. The standard deviation required to bring performance to 75 % was 0.176 near the centre and 0.0091 at the corner. A uniform comparison patch distributed the same luminance increment over the whole array. Relative to this equal-mean patch, the single bright tile changed the pooled response by +0.0351 near the centre and −0.0773 at the corner. A single flipped tile can therefore supply a positional cue even at the same physical mean luminance. Testing the grey-step hypothesis requires measuring texture visibility separately.

Offsets when one quantity is measured alone

If sharpness, lightness and space are one quantity seen three ways, a scale that measures one while treating the other two as fixed carries them into its result. The dark end of the lightness scales is consistent with this: the scales lie below a pure power near black by up to 0.07 (ref. 3), and a step set by spatial sampling, through optical blur or through the cone mosaic, may remove up to about two thirds of that departure. Letter acuity moves from −0.18 to 0.20 logMAR as contrast falls from −90 % to −5 % (ref. 18), and the depth carried by blur moves with adapting luminance along a U-shaped threshold⁴; in each case one scale shifts with a quantity held outside it. A further hypothesis is that every scale of lightness, acuity or depth measured alone carries such an offset, and that measuring the three together under one condition would shrink the offsets.

Evidence from the history of painting

Chronology

  • Egyptian two-dimensional art renders each element from its most recognisable angle and builds composite scenes in registers, not a view from one point; hierarchy is shown by scale; overlap places one flat figure behind another³⁹. These rank flat figures without thickness, an ordinal depth order, not spatial relation as defined here; shading and modelling are not described in these accounts³⁹.
  • The Greek account in Pliny begins painting with the outline of a person's shadow, then a single colour (monochrome), both flat figures, and only later has the art discover light and shade (lumen atque umbras), then add a highlight (splendor) and a tone between light and shade⁴⁰. Apollodorus of Athens, in the 93rd Olympiad (408–405 BC), is the first to render appearances⁴⁰; an ancient biographer names him the first to discover the mixing of colours and chiaroscuro⁴¹. The technique, skiagraphia or shadow-painting, is still seen in the light modelling of the late fourth-century BC mosaics at Pella⁴².
  • In Byzantine painting the modelling survived in a reduced, standardised form⁴². Gold grounds replaced depicted backgrounds; the gold is read in recent scholarship as light, and in the medieval reading as transcendental light⁴³.
  • A painters' handbook by a pupil in Giotto's line, surviving in a copy finished in 1437, credits Giotto with changing painting "from the Greek to the Latin" manner⁴⁴, and instructs the painter to give relief to figures by light and shade according to the windows of the place, since without it a work is "without relief"⁴⁴.
  • In Masaccio's Tribute Money (about 1425) light comes from one place outside the picture and casts the figures in light and shadow, a chiaroscuro that sculpts the bodies into three-dimensional shapes; earlier, Giotto's light had been flat and neutral from no identifiable source. The distant mountains are dimmer and paler than the foreground, an aerial perspective described as known in ancient Rome and lost until then⁴⁵.
  • Gold grounds were nearly eliminated in early Netherlandish painting from the mid-1420s in favour of depicted space, and by the late fifteenth century gold was a deliberate archaism⁴³.
  • Leonardo's notebooks (about 1490–1516) make relief the first aim of painting and give its means as three perspectives: of size, of colour and of distinctness²; they call shadow of the greatest importance in perspective, since without it solid bodies are ill-defined²; objects seen in light and shade show greater relief than those wholly in light or in shadow²; and an object in white and black shows the strongest relief². Sfumato, his gradation "without lines or borders, in the manner of smoke", softens the transitions between tones⁴⁶.

Linear perspective

Linear perspective exists as a means of depth: converging lines, foreshortening and sizes that diminish with distance. It supplies one of two layers of spatial information, the deformation of forms under projection, that is the change of their shape and size with depth. The other layer, the light-dark relation, is supplied by lightness gradation: the thickness of forms and the depth between them. Lines appear to carry the first layer only, and in an achromatic depiction they are themselves lightness steps: a boundary between two surfaces is a lightness difference, and so is a drawn line; the step at a sharp boundary between two large uniform areas is ΔL₁ = 0.030, and the step at which the same edge drawn as a 1 px line carries the same signal is ΔL₂ ≈ 0.07, both from ref. 3. A perspective construction in an achromatic image is therefore an arrangement of lightness steps in the plane; with no lightness difference there is no line and no perspective. Line-only interiors offer an illustrative example of what perspective gives without gradation: cafés in Seoul are built with every wall, floor, item of furniture and piece of tableware white and every edge outlined in black; they are real rooms, seen in exact perspective, yet they are described as a real world in two dimensions and as a cartoon or drawing⁴⁷˒⁴⁸. Their forms keep their real thickness and their true perspective; what is reduced to near-uniform white is the lightness gradation within and between surfaces, and operational reading of thickness appears to be reduced with it. Linear perspective thus appears to give the deformation layer rather than thickness. Leonardo counts the diminution of size among the three branches of perspective, with the diminution of colour and of distinctness², makes relief depend on light and shade, and calls shadow of the greatest importance in perspective because without it solid bodies are ill-defined²; where buildings seen above a wall appear of the same size, the lines of perspective cannot set their distances, and the change of colour through the air gives them, in proportion: a building five times as far is to be painted five times bluer². In the chronology above, modelling in light and shade supplies the second layer from the late fifth century BC on, and perspective construction, set out as a branch of its own in the notebooks of about 1490–1516 (ref. 2), systematises the first. Masaccio's fresco is described as combining light from one source with aerial perspective⁴⁵.

Where the sources disagree

The record is not a single rise. Light and shade are reported in Greek painting of the late fifth century BC and in antique aerial perspective, then reduced in Byzantine painting, then recovered from about 1300 to 1500 (refs 40, 42, 45). This is a fact of the record, not counter-evidence: where modelling in light and shade is reported, relief is reported with it, and where it is reduced, as on gold grounds, depicted space gives way⁴²˒⁴³. On Giotto the sources differ: the handbook credits him with the change⁴⁴, while the account of Masaccio describes Giotto's light as flat⁴⁵; both can hold if Giotto modelled figures without one light source. Overlap and registers in Egyptian scenes³⁹ rank flat figures that have no thickness; this ordinal depth order is not spatial relation as defined here, and it neither supports nor weakens the link between lightness and spatial relation. Under this definition, in the accounts cited²˒³⁹⁻⁴⁶ spatial relation in painting, that is the thickness of forms and the depth between them, appears only together with lightness gradation (shading, chiaroscuro, sfumato and aerial perspective), while those sources also note additional depth cues.

Discussion

The model joins a geometric-mean mid-grey, a spatial code and a visual threshold law. In the binary two-dimensional case q_code = (b/C)² follows from the number of elements. The adopted q_vis ∝ b^(√3/2) law describes the near-black task and constrains the ratio of comparison noise to pooled response gain in equation (8). With a common model anchor the visual readout changes less with defocus than the area-count step. The 1/30 black–white endpoint ratio, a raw V difference of 1/30 used for the edge calculation, and the increment threshold have distinct definitions and units. Their comparisons refer to the specified conditions.

The numerical and literature comparisons give mixed results, while the within-task human grey-discrimination experiment remains proposed below. The halftone relation agrees by construction, and fine screen rulings sit near the acuity limit at reading distance. A 1 px line needs a lightness step 2.1–2.5 times that of a boundary between areas, and letters need more elements as contrast falls, both in the direction the interchange gives. The Barten thresholds do not follow the binary count, but between a quarter and a half of the cutoff they rise with an average log slope near 2, which an area count with a fixed number of levels per element would give; across 8–500 cd/m², the sub-band fitted slopes run from 1.5 to 2.7 (1.46–2.71), and the point derivatives run from 1.06–1.15 at 0.25 u_c to 2.96–3.33 at 0.50 u_c. At the dark end, optical blur at zero geometric defocus in the assumed 7.75′ cell implied by 1/60, which has no independent grounds, or the cone spacing in the Riccò cell gives a step close to the one that fits CIE L* and Munsell best, while the diffraction-limited model with q₀ = 1/60 removes a third to two fifths. On the front-end sharpness side, numerical evaluation of raw V(I) at the chosen ΔV = 1/30 criterion puts both the best-phase 1 px (1.0′) grating cutoff and bright-side blur onset at b* = 1.41–1.67′ (q* = 0.033–0.046), converging on the daylight in-focus blur band and predicting conditional scenario polarity ratios of 3.31× for the edge shoulder and 23.72× for a far-field line extrapolation (n = 0.74, Gaussian PSF). In the pooled readout, the model predicts a strong dependence on the position of a binary halftone flip. At q_code = 1/30 a flip can yield different response differences and correct rates at the same array mean. The 12–39× response-threshold ratios in Table 9(e) compare the linearised independent-noise response thresholds with the illustrative response benchmark |ΔR_75| = 1/30. The history of painting, scoped to achromatic depiction and operational thickness judgments under the definition of spatial relation, is consistent with lightness carrying spatial relation: lightness gradation supplies the light-dark layer, the thickness of forms and the depth between them; linear perspective supplies the deformation layer and is itself an arrangement of lightness boundaries; and in the accounts cited, spatial relation appears only together with lightness gradation.

What remains to be measured

The following quantities remain open; each is stated at the strength the evidence allows, with the measurement that would settle it.

  • The trade between space and lightness. In the equal-area, equal-weight model with g equally spaced levels per element, the number of coded transitions in a region holding N resolved elements is N(g − 1) (giving N(g − 1) + 1 attainable levels), so a scene seen at a coarser spatial scale may show finer lightness steps, and the converse. The human grey-discrimination experiment proposed below would test whether visual resolution q_vis follows this rule.
  • The first step above black. The black end at 1/30 of white is likely near the first step the eye resolves on a cell of 25–35 elements; measuring the smallest luminance told apart from a dark ground on 5′ and 30′ targets, with the summation size measured independently, would settle it and tell whether C is the target or the summation area.
  • The element at the dark end. The departure of lightness scales near black is possibly set by optical blur or by the cone spacing in a cell of the size of the foveal complete-summation area, rather than by the diffraction limit alone; settling it needs the summation range and grey discrimination near black under one background, pupil, focus and task.
  • Simultaneous spatial weights and source-separated noise near black. No published study yet measures foveal spatial weighting templates wᵢ and source-separated internal noise (early receptor variance, shared correlation ρ and late decision noise σ_d²) simultaneously in the same photopic near-black patch-discrimination task. Combining centre, edge and surround perturbation templates with external-noise masking and double-pass consistency across pedestals (I₀ = 0.002 to 0.90) under one adapting surround—analysed under a specified covariance and response model with an explicit identifiability check—would close this empirical gap and directly calibrate q_vis near black.
  • Levels per element. The Barten thresholds suggest an effective 17–20 levels per element with m as the step, or 46–56 with the 2Ȳm conversion, at 80 cd/m²; grey discrimination with patterns of known element size would measure it directly.
  • Share of spatial information carried by lines. A further hypothesis is that lines, which carry only the deformation layer, convey about half of the spatial information of a scene, and lightness gradation the other half. A gauge-figure study of line drawings⁴⁹ measures the local surface orientation of isolated objects, a shape-reading task; it does not measure the thickness of forms or the depth between them. Operationalising any quantitative share such as half requires defining a baseline, a performance metric and a cue-combination rule for interactions across line-only, gradation-only and combined renderings of the same scenes in judgments of thickness and depth between forms.
  • Gradation and the reading of thickness. In the accounts cited²˒³⁹⁻⁴⁶, spatial relation between objects in a picture appears only with lightness gradation; overlap and registers rank flat figures, and linear perspective, itself an arrangement of lightness boundaries in an achromatic depiction, places forms and scales their size, while thickness comes from gradation within a surface. Line-only interiors, real rooms in exact perspective, serve as an illustrative example described as reading as flat drawings once gradation is reduced⁴⁷˒⁴⁸; the measurable question is how much operational judgements of curvature, thickness and distance between objects drop when gradation within surfaces is removed while the projected outlines stay identical.

Limitations

The element and the cell of the eye are not measured as such: the cone spacing, the Airy angle, optical blur and the Riccò diameter stand in for them as proxy scales, and the Riccò diameter depends on background and task. The 7.75′ cell implied by q₀ = 1/60 under k = 2 has no independent grounds, and the black end at 1/30 is read as a resolution limit only by assumption. The blur values rest on adult aberration norms, a Weber model of blur discrimination, a Gaussian PSF conversion κ_PSF = 0.425–0.50 and a root-sum-square of blur widths. In the stochastic readout model, the cone exponent n = 0.74, the input-equivalent macaque 1–10 Hz dark-light surrogate (620 R*/s, 95 % CI 480–835 R*/s) and correlated retinal noise come from primate physiology measured in different preparations and eccentricities, and no single dataset yet measures spatial weights and noise decomposition together in the human fovea near black; near-black thresholds therefore remain model calibrations pending same-task measurement. The Barten model is a fit, used here through its published implementation¹⁷. The halftone relation is exact for print but is an analogy for the retina. The art-historical evidence rests on translations, encyclopaedia entries and teaching texts rather than on specialist monographs. The dark-end test reuses the scales and grid of refs 3 and 4.

The visual exponent is applied within a specified near-black task, with the blur-width convention and reading cell fixed. A changed background, field, pedestal or task requires its own reference threshold. The joint dark-end example uses a shared model anchor. The absolute threshold and the separate weighting and noise terms require same-task measurements.

Testable predictions and limitations

Model predictions

  • Measured together under one condition, with pupil, focus, adapting luminance and element size fixed, the offsets of separate scales of lightness, acuity and blur-carried depth shrink.
  • Ordered dots and hatching matched in mean luminance give coding steps with exponents 2 and 1. Independent random dots have coverage fluctuations proportional to N^(−1/2). After texture falls below visibility, compare these engineering predictions with the visual thresholds measured at 75% correct for each pattern.
  • The first step above black, under two competing readings of the cell. With the square law and a hard cut-off, the cell that sets the step is C_eff = min(C_target, C_pool), where C_target is the side of the target and C_pool the side of the summation area, so that under k = 2 the step is q = (a/C_eff)². If the whole target is summed (C_pool ≥ 30′), a 30′ square gives a step 1/36 that of a 5′ square. Equal steps on the two targets need summation to saturate at or below 5′ (C_pool ≤ 5′); the common step then depends on C_pool, q = (a/C_pool)², and with a = 1′ it is 1/25 at C_pool = 5′ and 1/9 at 3′. For C_pool between 5′ and 30′, the 30′ step is (5′/C_pool)² times the 5′ step: saturation at 10′ leaves the 30′ step at 1/4 of the 5′ step. With C_pool measured independently, the experiment therefore tests both whether the two steps are equal and the absolute step each target is predicted to give. On bars that grow in one direction the step follows the number of elements along one axis (k = 1), on squares the area (k = 2).
  • At fixed adaptation and task, geometric defocus that increases optical blur raises the near-black visual threshold according to k_vis = √3/2. Agreement with a reference lightness scale depends on where its best-fitting join falls. In the separate bright-end calculation, the sharpness difference of depth steps of about 0.13–0.24 D is lost above about 1.2 × 10³–3.6 × 10⁴ cd/m², while larger steps retain it.
  • On a 30:1 edge viewed under controlled focus, blur onset shows a strong dark-versus-bright polarity asymmetry: under the n = 0.74 Gaussian-PSF, x_k = (k + 1/2)s model at ΔV = 1/30, the dark-side shoulder crosses threshold about three times earlier in blur width than the bright-side shoulder (3.31×), and an isolated thin white line on black survives heavier optical blur than a matched dark line on white (with the 23.72× ratio representing a wide-blur model extrapolation).
  • In near-black 2IFC patch discrimination under a fixed photopic surround, spatial perturbation templates (centre, edge and surround probes) will show foveal peak weighting rather than uniform area averaging (so a single flipped halftone unit is detected more readily at the patch centre than near its rim), while combined external-noise masking, double-pass repeats and pedestal/luminance sweeps—analysed under a specified covariance and response model with an identifiability check—will constrain early receptor noise (crossing from dark-light dominance below ~190–281 cd/m² under c_td = 12 to shot-noise dominance above it) separately from pedestal-invariant late decision noise σ_d².

Empirical test and falsification criteria

For a fixed pedestal, adapting surround, stimulus and reading cell, the joint model predicts a log–log slope of √3/2 between the 75% increment threshold and blur width. Doubling optical blur from b₀ predicts 1.823 times the threshold, compared with 2× under linear scaling (k = 1) and 4× under area counting (k = 2); an experiment testing √3/2 specifically must report whether it can distinguish √3/2 (1.823×) from 1 (2×) as well as from 2 (4×). Measure Q₀ and compare the curve with held-out blur widths. Systematic deviations beyond uncertainty under the specified conditions contradict the adopted visual law.

Three patterns are shown with the same black and white ends (a 30:1 range) and the same expected physical mean luminance, under controlled viewing distance, adapting luminance and pupil: a regular two-dimensional dot screen, parallel hatching, and random dots regenerated on every trial. Random dots are shown in two conditions, one with the global number of black dots fixed (holding the patch mean constant while local sub-cell coverage varies) and only their positions randomised, and one with the dot count random as well (matching the other patterns in expectation while the realised patch mean varies). Both the realised global mean across the patch and the independently measured weighted local coverage inside the pooling cell C are recorded for each interval and distinguished in the analysis, separating patch-mean fluctuations, local sub-cell coverage variance and observer discrimination in the N^(−1/2) term. For each pattern and coverage, two thresholds are measured as the element size or the viewing distance changes: the point at which the texture stops being visible, and the smallest coverage difference at which two adjacent grey fields are told apart. Adding a companion 2IFC perturbation, external-noise and double-pass block on near-black and mid-grey patches under the same surround—coupled with a specified covariance/response model and an explicit identifiability check—separates spatial weights wᵢ from correlated and late decision noise σ_d².

Regular dots and hatching give different area counts: N = (C/a)² for the dot screen and N = C/a for hatching, so their coded steps scale with the square and the first power of the element-to-cell ratio. For random dots the step is set by the N^(−1/2) fluctuation of coverage, estimated over the regenerated patterns. Results consistent with one quantity (conditional on this modelled perturbation-and-identifiability design): once the texture is invisible, the discrimination step of each pattern follows its own coded step, with the exponents 2, 1 and the random-dot fluctuation, and meets the count where the texture disappears; blur onset is asymmetric between dark and bright sides; and single-unit halftone visibility depends on radial position within the weighting profile and follows the calibrated receptor-plus-late noise curve. Results against it (under the same controlled design): equal discrimination steps for the three patterns at matched expected mean luminance once the texture is invisible, a step that does not change with element size, a dark-end departure that does not change with pupil or focus, a blur-carried depth threshold that stays flat across adapting luminance, symmetric dark and bright blur onset on a 30:1 edge, or uniform-patch thresholds near black that violate the calibrated dark-to-shot transition between 80 and 400 cd/m² once shared and late noise are controlled.

Published results at the edges of the exchange

Three published results bear on where the exchange applies, and each is consistent with the definitions. For letters larger than 0.75° the contrast threshold stays near 1.6 % over 0.75–12° and 7–514 cd/m² (ref. 50): within the square-law hard-cutoff model this plateau requires summation to saturate by C_pool ≤ 0.75°, so once a form is well above the sharpness limit its size no longer sets the threshold and size enters only through sharpness near the limit. Position is judged to 4–5″ at contrasts of 0.22 and above⁵¹, a twelfth to a fifteenth of the 1′ element: the lightness profile across elements carries positional information finer than the element count, so lightness carries visual information below the size of one element. Depth from shading grows with signed-log₁₀ contrast by a similar descriptive slope—about 1.30′ of matched disparity per log₁₀ unit across the five-observer zero-test-disparity series in Fig. 4A—in two configurations whose modulation spatial frequency varied sevenfold (0.26 cycles per degree vs 1.8 cycles per degree) at fixed target size⁵²: this shows comparable contrast scaling across a sevenfold shift in modulation spatial frequency rather than proving sevenfold spatial-size independence, while a size that is too small acts through sharpness. Within the vision, halftone and contrast-sensitivity literature reviewed for this paper (refs. 1–53), no study varies sharpness, lightness and spatial sampling jointly under one condition to test whether the exchange fails.

Methods

Computation

All numbers were computed in Python 3.14.6 with the standard library only, each a second way. In paper-spatial-lightness-sampling-20261125.py: Nyquist intervals by two formulas; the quantiser bound and RMS on a grid of 300,000 values; halftone levels by formula and by enumeration of cell coverages; rulings in cycles per degree by the angle per millimetre and by the angle of one period; the Airy angle with 1.22 and with the first zero of J₁; the Barten cutoff by bisection and by secant, and local slopes with two step sizes; and the dark-end toe checked against the values of ref. 4 (largest difference 3.6 × 10⁻⁶). The Barten model uses the published default constants for observers aged 20–30, a 2° square field and the model's own pupil formula. Excluding all least-squares-versus-endpoint-secant slope rows (which compare two distinct slope estimators and differ by up to 0.0288, reported as 0.029), all remaining non-slope pairs in that script agree within 0.0081 (maximum 0.008072). The blur and depth-of-field values are those of ref. 4. The blur-onset, spatial-weights, photopic-noise and halftone-visibility numbers (Tables 6–10) were computed in paper-spatial-weights-noise-20261125.py with deterministic RNG seed 20261125, each quantity checked a second way: exact analytical Gaussian step and line convolutions cross-checked against direct 1D midpoint numerical convolution (maximum difference 4.3 × 10⁻⁶ across the Table 6 sweep); a 200-harmonic Fourier series for the 30:1 square-wave grating cross-checked against a spatial error-function sum (profile difference 3.3 × 10⁻¹⁶; cutoff difference 2.2 × 10⁻¹⁶); threshold widths σ_h*, optical root b(D, 0) = √2′ and Z_75 solved by bisection and by secant or Newton iteration (maximum difference 1.2 × 10⁻¹²); endpoint slope ratio V′(1/30)/V′(1) checked analytically against central finite differences (1.3 × 10⁻⁸); discrete 2D hexagonal cone-lattice counts and N_eff compared with the analytical continuum tanh formula (smooth Gaussian N_eff agreement within 0.71 cones for σ_w ≤ 2.0′ at s_cone = 0.58′ and 3.08 cones at s_cone = 0.50′, and 6.66 cones for the hard circular boundary at σ_w = ∞); Watson–Yellott photopic calibration checked by direct troland and radius-squared area forms (maximum difference 1.8 × 10⁻¹²); asymptotic variance slopes checked analytically (2n − 1 = +0.48, 2n − 2 = −0.52) against numerical log–log slopes on [10⁻⁶, 10⁻⁴]; equicorrelated quadratic forms wᵀ Σ w checked by the O(N) identity against the O(N²) explicit double sum (difference 2.8 × 10⁻¹⁷ at ρ = 0.10, N = 211); first-order variance propagation checked against exact Poisson Monte Carlo sampling at 80 and 400 cd/m² (Knuth / Hörmann PTRS, 20,000 single-cone draws and 5,000 full 211-cone lattice trials, confirming about 1.2 % agreement—maximum 1.22 %—at the sampled pedestals under the Barlow additive dark-light operating point); and 2D binary halftone disk PSF convolutions evaluated by numerical 1D analytical erf-chord quadrature (n = 60 and n = 120 panels, plus 160 × 160 2D Cartesian quadrature, maximum profile difference 1.3 × 10⁻⁴) with O(N) against O(N²) noise covariance (internal 60-vs-120-panel maximum difference 0.031 on ideal d′ = 60.3 and ≤ 1.5 × 10⁻⁴ on P_correct). An independent from-scratch numerical re-implementation (direct Gaussian interval integration, axial integer lattice enumeration, exact Poisson response-moment recurrence and chi-square-mixture Gaussian disc integration) confirmed all 251 printed cells of Tables 6–8, the finite first-order values of Table 9, exact-moment agreement at 200 cd/m², 125 ms across 1,357 inputs I ≥ 1/30 (first-order/exact clipped SD ratios 0.992–0.999), and all 24 Table 10 cases (converged P_correct difference ≤ 2.3 × 10⁻⁴ against 60-panel quadrature and ≤ 8.1 × 10⁻⁵ against 120-panel quadrature). Separately from Tables 6–10, paper-spatial-weights-noise-independent-20261125.py implements an independent complementary square-tile and equal-mean positional-cue control—rather than a line-by-line duplication of Tables 6–10—under separate optical, photopic-conversion and black-limit settings. It used a 200 cd/m² reference white, a 50.6 cd/m² adapting surround, an unblurred black level of 1/30 of white, 200 ms per interval and 1 % admixture of adapting-surround luminance. The Gaussian point-spread function had a full width at half maximum of 1.4′. The normalised Gaussian pooling weights had a standard deviation of 1.7′ on a hexagonal cone lattice with 0.55′ spacing, truncated at 4.5 standard deviations. Mean captures at reference white were 5,568 photoisomerisations per cone per interval, calculated with the light-adapted pupil model, a Stiles–Crawford effective pupil area of 6.96 mm² and a scenario conversion of c_td = 20 photoisomerisations per cone per second per troland (at the upper end of the illustrative 8–20 R* cone⁻¹ s⁻¹ td⁻¹ photopic band²⁷˒²⁸, 2.3× the Table 8 baseline κ = 2,418 R* at c_td = 12 and T = 125 ms, lowering pure shot SD by √2.3 ≈ 1.52× at fixed normalised intensity and reinforcing that independent photon noise alone lies far below 1/30). Pooled response differences came from 20,000 paired Poisson draws per condition and were checked by summing individual cone response moments over the Poisson distribution; the script also evaluated the I = 10⁻⁶ discrete sub-single-photon shot limit (linear-to-exact SD ratio 2.87× at κ = 5,568 R*, versus 3.59× at κ = 2,418 R*). The added Gaussian comparison-noise standard deviations were sensitivity parameters. As a sensitivity check, using n = 0.80 raised the corner correct rate to 74.2 % under the same noise setting. Paupoo et al. used this exponent to model cone current suppression by steady backgrounds in a human full-field electroretinogram⁵³. The exponent in that fit describes a different response from the local near-black readout modelled here.

For the joint dark-end comparison, compute b with the same diffraction, higher-order aberration and geometric-defocus widths as the optical benchmark. Use the b₀ at 1,000 cd/m² and 0 D, divide each b by b₀, and calculate T = Q₀(b/b₀)^(√3/2). Join the linear dark end to Y^log₃₀4 at T and compare its RMS residual with the pure power over the same points below Y = 0.1. The anchor Q₀ = (b₀/C)² is an illustrative model choice. The direct piecewise calculation and the existing scale-fitting routine agree.

Data and code availability

The script paper-spatial-lightness-sampling-20261125.py and its output table paper-spatial-lightness-sampling-20261125.csv (every quantity with its second computation) reproduce Tables 1–5 and the sampling-exchange numbers, including the dark-end 49–67 %, the share of the RMS departure of CIE L* below Y = 0.1 removed with the cone spacing as the element in the Riccò cell (Table 5); the script paper-pupil-derivation-20261125.py and its 2,198-point table paper-pupil-derivation-20261125.csv reproduce the 63–69 % (64–68 % for Munsell) optical-blur dark-end values in a 7.75′ cell and the 0.13–0.24 D bright-end depth thresholds⁴. Both legacy script–CSV pairs were first published at https://github.com/ariclue/Laboratory/tree/ae772fee085ef3f02acdfe06df47b6229f139704/papers/sharpness-lightness-space. The four companion files for Tables 6–10 and the independent controls—paper-spatial-weights-noise-20261125.py with its 624-row dual-computation output table paper-spatial-weights-noise-20261125.csv (reproducing Tables 6–10 and all Monte Carlo checks), and paper-spatial-weights-noise-independent-20261125.py with its six-column CSV paper-spatial-weights-noise-independent-20261125.csv (recording the independent square-tile, equal-mean, n = 0.80 and I = 10⁻⁶ discrete shot controls)—run in Python 3.14.6 with the standard library only and together with the explicit joint-model specification (joint-model.md), dual-method verification script (joint-model.py), four derived CSV tables and two vector figures (joint-crossings.svg and joint-phase.svg), are published alongside the earlier pairs in the unified public tree at https://github.com/ariclue/Laboratory/tree/8f1d3e318f07f11cdc8c999702e8ecb730c37d62/papers/sharpness-lightness-space under the MIT licence (code) and CC BY 4.0 (data and figures).

Declarations

Funding: This research received no external funding.

Competing interests: The author declares no competing interests.

Data and code availability: Python scripts and data reproducing all numerical evaluations in this paper are openly available on GitHub (github.com/ariclue/Laboratory; code under MIT, data under CC BY 4.0).

Use of generative AI: Generative AI tools were used during the preparation of this work (Claude Opus 5.5, Anthropic; GPT-6.2 Sol, OpenAI; Gemini 4 Neon, Google). After using these tools, the author reviewed, verified and edited the content as needed and takes full responsibility for the content of this paper.

References

1.

Halftone. Wikipedia (accessed 25 November 2026).

2.

Leonardo da Vinci. The Notebooks of Leonardo da Vinci, vol. 1, ed. and trans. J. P. Richter (1883; Project Gutenberg transcription), §§17, 111, 153, 285, 295.

3.

Alchemist, H. A geometric-mean prediction for middle grey from a cone-response model. Ariclue research (2026) (companion code and curves pinned at https://github.com/ariclue/Laboratory/tree/8f1d3e318f07f11cdc8c999702e8ecb730c37d62/papers/middle-grey). doi:10.5281/zenodo.24540310

4.

Alchemist, H. Pupil derivation of the dark-end departure. Ariclue research, computation and data, https://github.com/ariclue/Laboratory/tree/ae772fee085ef3f02acdfe06df47b6229f139704/papers/sharpness-lightness-space (2026).

5.

US Patent 7,110,142, Systems and methods for sensing marking substrate area coverage using a spectrophotometer (Yule–Nielsen correction, equation 2).

6.

Yule, J. A. C. & Nielsen, W. J. The penetration of light into paper and its effect on halftone reproduction. Proc. TAGA 3, 65–76 (1951); as cited in Dot gain, Wikipedia (accessed 25 November 2026).

7.

Spohn, D. Apple LaserWriters: screen frequency and gray levels. The Information Alley, Apple Computer.

8.

US Patent 6,266,154, Grayscale enhancement system and method.

9.

US Patent 7,602,530, Creating high spatial frequency halftone screens with increased numbers of printable density levels.

10.

Bayer, B. E. An optimum method for two-level rendition of continuous-tone pictures. IEEE Int. Conf. Commun. 1, 11–15 (1973); as cited in Ordered dithering, Wikipedia (accessed 25 November 2026).

11.

Film grain (Selwyn granularity). Wikipedia (accessed 25 November 2026), citing Bjelkhagen, Silver-halide Recording Materials (Springer, 1995).

12.

Riccò's law. Wikipedia (accessed 25 November 2026), citing Riccò (1877) and Schwartz, Visual Perception (2004).

13.

Volbrecht, V. J., Shrago, E. E., Schefrin, B. E. & Werner, J. S. Spatial summation in human cone mechanisms from 0° to 20° in the superior retina. J. Opt. Soc. Am. A 17, 641–650 (2000). doi:10.1364/JOSAA.17.000641

14.

Adobe InDesign CS4 User Guide, About halftone screen frequency, p. 638.

15.

DICOM PS3.14 2024c, Grayscale Standard Display Function, Annex A.2. NEMA.

16.

Barten, P. G. J. Contrast Sensitivity of the Human Eye and Its Effects on Image Quality (SPIE, 1999). doi:10.1117/3.353254

17.

Colour developers. colour.contrast.barten1999, colour-science (BSD-3-Clause), source code.

18.

Pluháček, F., Siderov, J. & Macháčová, I. Crowding can impact both low and high contrast visual acuity measurements. Sci. Rep. 12, 16338 (2022). doi:10.1038/s41598-022-20479-y

19.

Wang, M. & Parker, K. J. A metric to evaluate the texture visibility of halftone patterns. Human Vision and Electronic Imaging VI, Proc. SPIE 4299, 163–174 (2001). doi:10.1117/12.429486

20.

Snellen, H. Probebuchstaben zur Bestimmung der Sehschärfe (P. W. van de Weijer, Utrecht, 1862), text p. 1.

21.

Tuten, W. S. et al. Spatial summation in the human fovea: do normal optical aberrations and fixational eye movements have an effect? J. Vis. 18(8), 6 (2018). doi:10.1167/18.8.6

22.

Shannon, C. E. Communication in the presence of noise. Proc. IRE 37, 10–21 (1949); as cited in Nyquist–Shannon sampling theorem, Wikipedia (accessed 25 November 2026).

23.

Quantization (signal processing). Wikipedia (accessed 25 November 2026), citing Bennett, Spectra of quantized signals, Bell Syst. Tech. J. 27 (1948).

24.

Watson, A. B. & Yellott, J. I. A unified formula for light-adapted pupil size. J. Vis. 12(10), 12 (2012). doi:10.1167/12.10.12

25.

Levi, D. M. & Klein, S. A. Classification images for detection and position discrimination in the fovea and parafovea. J. Vis. 2(1), 46–65 (2002). doi:10.1167/2.1.4

26.

Field, G. D. et al. Functional connectivity in the retina at the resolution of photoreceptors. Nature 467, 673–677 (2010). doi:10.1038/nature09424

27.

Banks, M. S., Geisler, W. S. & Bennett, P. J. The physical limits of grating visibility. Vision Res. 27, 1915–1924 (1987). doi:10.1016/0042-6989(87)90057-5

28.

Cottaris, N. P., Jiang, H., Ding, X., Wandell, B. A. & Brainard, D. H. A computational-observer model of spatial contrast sensitivity: effects of wave-front-based optics, cone-mosaic structure, and inference engine. J. Vis. 19(4), 8 (2019). doi:10.1167/19.4.8

29.

Cottaris, N. P., Wandell, B. A., Rieke, F. & Brainard, D. H. A computational observer model of spatial contrast sensitivity: effects of photocurrent encoding, fixational eye movements, and inference engine. J. Vis. 20(7), 17 (2020). doi:10.1167/jov.20.7.17

30.

Angueyra, J. M. & Rieke, F. Origin and effect of phototransduction noise in primate cone photoreceptors. Nat. Neurosci. 16, 1692–1700 (2013). doi:10.1038/nn.3534

31.

Hass, C. A., Angueyra, J. M., Lindbloom-Brown, Z., Rieke, F. & Horwitz, G. D. Chromatic detection from cone photoreceptors to V1 neurons to behavior in rhesus monkeys. J. Vis. 15(15), 1 (2015). doi:10.1167/15.15.1

32.

Ala-Laurila, P., Greschner, M., Chichilnisky, E. J. & Rieke, F. Cone photoreceptor contributions to noise and correlations in the retinal output. Nat. Neurosci. 14, 1309–1316 (2011). doi:10.1038/nn.2927

33.

Legge, G. E., Kersten, D. & Burgess, A. E. Contrast discrimination in noise. J. Opt. Soc. Am. A 4, 391–404 (1987). doi:10.1364/josaa.4.000391

34.

Burgess, A. E. & Colborne, B. Visual signal detection. IV. Observer inconsistency. J. Opt. Soc. Am. A 5, 617–627 (1988). doi:10.1364/josaa.5.000617

35.

Malo, J., Esteve-Taboada, J. J., Aguilar, G. M., Maertens, M. & Wichmann, F. A. Estimating the contribution of early and late noise in vision from psychophysical data. J. Vis. 25(1), 12 (2025). doi:10.1167/jov.25.1.12

36.

Whittle, P. Increments and decrements: luminance discrimination. Vision Res. 26, 1677–1691 (1986). doi:10.1016/0042-6989(86)90055-6

37.

Shooner, C. & Mullen, K. T. Enhanced luminance sensitivity on color and luminance pedestals: threshold measurements and a model of parvocellular luminance processing. J. Vis. 20(6), 12 (2020). doi:10.1167/jov.20.6.12

38.

Barlow, H. B. Retinal noise and absolute threshold. J. Opt. Soc. Am. 46, 634–639 (1956). doi:10.1364/JOSA.46.000634

39.

Calvert, A. Egyptian art. In Introduction to Art (Lumen Learning, SUNY).

40.

Pliny the Elder. Naturalis Historia 35.15–16, 35.29, 35.60–61 (Latin text, LacusCurtius).

41.

Plutarch. De gloria Atheniensium 2 (Moralia 346A), trans. F. C. Babbitt (Loeb, 1936; LacusCurtius).

42.

Chiaroscuro. Wikipedia (accessed 25 November 2026).

43.

Gold ground. Wikipedia (accessed 25 November 2026), citing Pächt, Book Illumination in the Middle Ages (1986), and Nuechterlein, From gold grounds to depicted space.

44.

Cennini, C. The Book of the Art of Cennino Cennini, trans. C. J. Herringham (George Allen & Unwin, 1899; 1922 printing), chapters 1 and 9.

45.

The Tribute Money (Masaccio). Wikipedia (accessed 25 November 2026), citing Gardner's Art through the Ages, pp. 599–600.

46.

Sfumato. Wikipedia (accessed 25 November 2026), citing Earls, Renaissance Art: A Topical Dictionary (1987), p. 263.

47.

El Saady, A. Optical illusion makes this café look like a cartoon. Arch2O (about 2018).

48.

Guido, G. Breakfast in a cartoon at Cafe Yeonnam-dong 239-20. Collater.al.

49.

Cole, F., Sanik, K., DeCarlo, D., Finkelstein, A., Funkhouser, T., Rusinkiewicz, S. & Singh, M. How well do line drawings depict shape? ACM Trans. Graph. 28(3) (2009). doi:10.1145/1531326.1531334

50.

Zhang, Pelli & Robson (1989), as cited in Pelli, D. G. & Bex, P. Measuring contrast sensitivity. Vision Res. 90, 10–14 (2013). doi:10.1016/j.visres.2013.04.015

51.

Wehrhahn, C. & Westheimer, G. How vernier acuity depends on contrast. Exp. Brain Res. 80, 618–620 (1990). doi:10.1007/BF00228001

52.

Chen, C.-C. & Tyler, C. W. Shading beats binocular disparity in depth from luminance gradients. PLoS ONE 10, e0132658 (2015). doi:10.1371/journal.pone.0132658

53.

Paupoo, A. A. V., Mahroo, O. A. R., Friedburg, C. & Lamb, T. D. Human cone photoreceptor responses measured by the electroretinogram a-wave during and after exposure to intense illumination. J. Physiol. 529, 469–482 (2000). doi:10.1111/j.1469-7793.2000.00469.x