Saturation difference from a zero-saturation anchor in a prism model of colour and lightness

Abstract

Existing colour models do not explain a basic observation of surface colour: colours arranged around a perceptually balanced hue ring appear comparable in visual strength on a white ground even though their luminances differ by more than an order of magnitude (from Y = 0.072 for blue to Y = 0.928 for yellow; luminance contrast 8.59:1 against 1.07:1 on white, and cone-response lightness difference 0.680 against 0.016). Because companion Papers 1 and 2 already showed that legacy colour spaces do not calibrate achromatic lightness accurately, every quantitative check in this paper is built strictly from physical radiometry, measured physiological cone fundamentals (Stockman–Sharpe 2° and Hunt–Pointer–Estevez HPE-LMS) and the cone-response lightness scale of Papers 1–2 (V(I) = I^n / (I^n + σ_R^n), n = 0.74, σ_R = 1/√30, mapping a 30:1 material range symmetrically to 0.221–0.779; photopic Barlow dark-light floor I_eff = I + μ_dark/κ giving 0.216–0.783 at 200 cd/m²), with zero matrices or coordinates borrowed from OKLab or CIELAB. This physiological foundation underpins the standalone π-free colour model Vela (V-Prism 30) (formalised in companion Paper 4 and released openly under CC0 1.0 / MIT). For the surface-colour and unfolding analysis in this paper, colour is written in three coupled coordinates: lightness L along the vertical axis, circular hue angle H ∈ [0°, 360°), and relative saturation S ∈ [0, 1] with S = 0 on the entire black–white axis. Two mirror-paired three-dimensional gamuts (X = H, Y = L, Z = S and X = S, Y = L, Z = H) unfold the closed colour solid along a chosen seam H₀ and curl continuously back into a double cone as a curvature parameter k runs from 0 to 1. Seven standalone quantitative checks are reported: (1) uniform ΔS = 1.00 across full primaries on white where luminance contrast varies 8.0× and Barlow ΔV_norm varies 42.5×; (2) an uncoupled three-channel V(I) response cube with strictly straight edges (0.0000 bulge) and 61.44° apex angle versus physiological HPE-LMS projections (8.98× raw chroma ratio, 0.0490 dark-edge bulge under Barlow dark light versus 0.1023 under a piecewise linear toe, cut to 4.51× by zero-fit physical MacAdam cardinal-span normalisation); (3) hue-dependent lightness–saturation slopes in pure HPE-LMS + V_Barlow (yellow bright/dark ratio 60.1× versus blue 0.47×); (4) optic-nerve stimulation as an alternative to colour psychology—among passive diffuse primaries, red uniquely maximises simultaneous dual-ground lightness headroom and saturation (H_L · S = 0.404 versus 0.016 for yellow), while Stokes-shift fluorescent pigments exceed the passive MacAdam limit (β(λ) > 1, S_eff = 1.35–1.65, pushing joint white visibility E_W to 2.62–3.20 and Valdez–Mehrabian arousal to +0.716); (5) on the 25 MacAdam (1942) chromaticity discrimination ellipses at Y = 0.50, pure physiological HPE-LMS + V_Barlow with zero fitted parameters cuts area anisotropy 9.3× relative to CIE xy (74.22× down to 7.96×, radius CV 28.5 %), and normalising the two cardinal axes by their physical Rösch–MacAdam spans (ratio 4.162×) drops mean ellipse aspect from 6.82 to 2.44; (6) projecting all 321 CIE 1931 2° spectral wavelengths (380–700 nm) and 4,288 Rösch–MacAdam optimal surface spectra (D65) directly through Stockman–Sharpe 2° and HPE-LMS cones with V_Barlow yields zero negative excitations and exposes the pure physiological 5.6–6.4× spectral-overlap anisotropy; and (7) mapping all 2,734 real physical pigment chips of Newhall, Nickerson and Judd (1943) directly into physiological HPE-LMS + V_Barlow versus V_toe isolates smooth dark-end calibration (V = 1–2, avoiding V_toe's 1.28× gain discontinuity), bright-end Naka–Rushton receptor saturation (0.78× to 0.64× at V = 7–9, matching analytic Y^(2/3) V'_Barlow(Y)), and high physical relative saturation where lightness contrast vanishes (5Y 9/20: ΔL_white = 0.060 yet S_MacAdam = 0.970). Falsifiable psychophysical tests and the outcomes that would contradict the theory are stated.

Introduction

The observation

On a white surface, a pure yellow patch (#FFFF00, relative luminance Y = 0.9278) sits only 1.07:1 below white in physical luminance contrast and only ΔV_norm = 0.016 on the Paper 2 Barlow cone-response lightness scale, yet it stands out immediately against white as a vivid coloured shape. A pure blue patch (#0000FF, Y = 0.0722) sits at 8.59:1 luminance contrast and ΔV_norm = 0.680. Even in a calibrated 23-hue chart palette built for balanced visual weight around the hue circle, yellow (#FFD000) carries 1.47:1 luminance contrast on white (ΔV_norm = 0.095) while red (#FD0C00) carries 4.02:1 (ΔV_norm = 0.405) and blue (#2354D9) carries 6.28:1 (ΔV_norm = 0.565). Across a perceptually balanced hue ring, lightness is not uniform, yet perceived chromatic presence remains comparable.

The gap in luminance-based colour models

Luminance-only contrast rules (such as WCAG relative luminance³ or lightness-only slices ΔL of CIELAB¹ and OKLab²) treat white solely as the upper endpoint of lightness (Y = 1). Under a luminance-only reading, any colour close to white in luminance is predicted to carry near-zero contrast against white, whereas full CIELAB and OKLab spaces already carry chromatic coordinates (a*, b* and a, b) alongside ad-hoc lightness corrections such as the Helmholtz–Kohlrausch (H–K) boost⁴˒⁵. The empirical question is therefore whether gamut-relative saturation S predicts visual prominence better than both luminance-only rules and full colour-difference models. Conversely, phenomenological systems built directly from human colour judgements, notably Ostwald’s double cone and the Swedish Natural Color System (NCS)⁶, place every hue inside an equilateral nuance triangle bounded by white, black and full colour (w + s + c = 1), without deriving the black and white endpoints from receptor response or spatial sampling.

Hypothesis: white as zero saturation and saturation difference as the chromatic variable

This paper connects the achromatic foundation of companion Papers 1 and 2⁷˒⁸ to chromatic perception through four linked proposals. First, white and black play a dual role: they are the endpoints of lightness, and they are simultaneously the zero-saturation reference (S = 0). Second, chromatic visibility against a white or grey ground is governed primarily by saturation difference ΔS measured from that zero-saturation anchor, rather than by lightness difference ΔL alone; lightness enters because changing lightness alters the available saturation envelope. Third, when the black and white endpoints are fixed by the cone-response and dark-light formulas of Papers 1 and 2 and colour is expressed in its three native coordinates (H, L, S), the underlying geometric solid approaches a triangular prism when unfolded and a symmetric double cone when curled, with asymmetries in standard LMS projections read as artefacts of measuring a saturation-driven signal on a luminance-weighted ruler. Fourth, emotional and arousal responses widely attributed to "colour psychology" are more parsimoniously explained by the magnitude of optic-nerve stimulation produced by purity (saturation) difference and simultaneous lightness contrast—accounting both for the dominance of red in high-chroma passive imagery⁷ and for the unmatched stimulating power of fluorescent colours.

Definitions

  • Relative luminance Y: diffuse surface luminance normalised to reference white (W = 1, real surface black B = 1/30; Papers 1 and 2⁷˒⁸). For fluorescent surfaces, total radiance factor β_T can exceed 1.0 when short-wavelength photons are re-emitted in the visible band.
  • Cone lightness response V(I): V(I) = I^n / (I^n + σ_R^n) with n = 0.74 and σ_R = 1/√30 = 18.26 % (Paper 1⁷, maximising endpoint response difference over the physical 30:1 range Y ∈ [1/30, 1]). Under the photopic Barlow dark-light floor of Paper 2⁸ (200 cd/m² white, 25 % grey surround L_A = 50 cd/m², D = 3.203 mm, c_td = 12 R* cone⁻¹ s⁻¹ td⁻¹, dark light 620 R*/s), effective input is I_eff = I + δ with δ = μ_dark/κ = 0.03205. Here σ_R = 1/√30 is held fixed to inspect the offset curve V_Barlow(I) = V(I + δ) directly, mapping Y ∈ [0, 1] to V ∈ [0.2163, 0.7828] (span 0.5665; Tables 1–7 normalise against V_Barlow(0) on [0, 1], while physical 30:1 surface bounds use [1/30, 1]). By contrast, re-applying Paper 1's endpoint-difference maximisation on I_eff over [B, W] = [1/30, 1] would give σ_eff = √((B + δ)(W + δ)) = 0.2598 and a physical half-response at I = σ_eff − δ = 22.77 % of white. Keeping σ_R fixed cleanly separates the two conditions (18.26 % vs 22.77 %).
  • Hue angle H: circular coordinate H ∈ [0°, 360°) specifying chromatic direction around the achromatic spine.
  • Absolute chroma C: radial distance from the achromatic axis in a given colour space (C = 0 on the black–white spine).
  • Relative saturation S: normalised chromatic strength S ∈ [0, 1] for passive diffuse surfaces (S = 0 along the entire black–white axis; S = 1 on the passive boundary). For fluorescent re-emitters exceeding the passive MacAdam boundary, effective saturation S_eff > 1.
  • Saturation difference ΔS: |S₁ − S₂|. Against any white or neutral grey ground (S₂ = 0), ΔS = S₁ directly.
  • Lightness–saturation coupling envelope C_max(L, H): upper bound on chroma achievable at lightness L and hue H, vanishing at both achromatic endpoints (C_max(L_B, H) = C_max(L_W, H) = 0) and peaking at a hue-dependent cusp (L_cusp(H), C_cusp(H)).
  • Dual-ground lightness headroom H_L: min(|1 − L_Vnorm|, L_Vnorm), measuring how much lightness contrast a colour preserves simultaneously against both white and black grounds.
  • Dual three-dimensional gamuts: Gamut A maps (X, Y, Z) = (H − H₀, L − L₀, S); Gamut B swaps the horizontal axes to (X, Y, Z) = (S, L − L₀, H − H₀), where H₀ is the unfolding seam angle and L₀ is the lightness origin.

The saturation-difference model

Lightness–saturation coupling

Because both black (L = L_B) and white (L = L_W) carry zero saturation, moving lightness L toward either endpoint necessarily compresses available chroma to zero. For any hue H, chroma is bounded by a lower (black-to-cusp) branch and an upper (cusp-to-white) branch:

C(L, H, S) = S · C_max(L, H), S ∈ [0, 1], H ∈ [0°, 360°)(1)

In the first-order triangular envelope—exact for optimal linear surfaces and for an uncoupled three-channel response cube—the upper bound is piecewise linear in L:

C_max(L, H) = C_cusp(H) · (L − L_B) / (L_cusp(H) − L_B) [L_B ≤ L ≤ L_cusp(H)](2)
C_max(L, H) = C_cusp(H) · (L_W − L) / (L_W − L_cusp(H)) [L_cusp(H) < L ≤ L_W](3)

Equations (1)–(3) express the coupling directly: holding absolute chroma C fixed while changing L alters S = C / C_max(L, H) and forces C to clip once C exceeds C_max(L, H); holding relative saturation S fixed while changing L changes C along slopes that differ sharply across wavelengths (Table 3).

White as zero saturation and joint chromatic visibility

When a chromatic patch (H, L, S) sits on a white ground (L_W, S = 0), the observer receives both an achromatic lightness difference ΔL = |L_W − L| and a chromatic saturation difference ΔS = |S − 0| = S. Under the hypothesis of this paper, perceived visibility against white does not vanish as ΔL → 0 because ΔS remains maximal:

E(H, L, S) = √((ΔL)² + (α(H) · ΔS)²), ΔS = |S − S_bg|(4)

Here α(H) > 0 weights the saturation-difference channel relative to the lightness channel. Below, α = 1.94 (the ratio |0.60 / 0.31| of standardised saturation-to-brightness slopes in Valdez and Mehrabian¹⁶) is used strictly as an illustrative parameter: those coefficients come from standardised emotional arousal regressions, whereas equation (4) requires a visual-prominence weight; emotional arousal and visual prominence therefore form separate hypotheses whose parameters must each be estimated from their own tasks. Crucially, substituting gamut-relative S = C / C_max(L, H) directly into equation (4) conflates proximity to the gamut boundary with perceived prominence near white: for example, along the linear sRGB boundary path (1, t, t) as t → 1, a patch stays maximally saturated for its lightness (S ≡ 1) while its absolute chroma C → 0 and lightness contrast ΔL → 0, so equation (4) approaches α(H) > 0 up to pure white and jumps discontinuously to 0 at pure white (S = 0 by convention). This approaching-white limit—where a colour remains as saturated as possible at its lightness while becoming harder to distinguish from white—is the sharpest discriminating test across Papers 3 and 5 between relative saturation S, absolute opponent drive C̃, and full colour-difference spaces (CIELAB ΔE, OKLab ΔE). At moderate lightness and isoluminance (ΔL = 0, C_max > 0), equation (4) reduces to E = α(H) · ΔS, consistent with Mullen's finding⁹ and Switkes and Crognale's suprathreshold contrast matching¹⁰.

Dual 3D coordinates and continuous prism-to-cone mapping

Two mirror-paired Cartesian gamuts share the vertical lightness axis Y = L − L₀ and swap hue and saturation on the horizontal plane (Gamut A: X = H, Z = S; Gamut B: X = S, Z = H). Shifting the seam H₀ rotates which hue sits at the cut edges of the unfolded solid, while shifting L₀ repositions the vertical origin (L_B, midpoint 0.5, or cusp-aligned). Introducing a continuous curvature parameter k ∈ [0, 1] with centred hue coordinate u_c = ((H − H₀) mod 360°)/360° − 0.5 ∈ [−0.5, 0.5], bend angle φ = 2π k u_c, and base arc radius ρ(k) = W(1 − k)/(π k) maps both unfolded gamuts smoothly onto a closed three-dimensional cone:

p_H = (ρ(k) + r) sin φ, p_S = (ρ(k) + r) cos φ − ρ(k)(5)

Gamut A takes (X, Z) = (p_H, p_S) and Gamut B takes (X, Z) = (p_S, p_H). As k → 0⁺, (p_H, p_S) → (2W u_c, r) (exact unfolded prism); at k = 1, ρ(1) = 0 and the achromatic spine r = 0 collapses onto the vertical axis (0, Y, 0), closing the solid into a three-dimensional double cone with no self-intersection (Fig. 2).

Fig. 2 | Cross-section geometry across three formulations: (a) uncoupled 3-channel V(I) response cube (straight edges, 61.44° apex, V ∈ [0.216, 0.783]); (b) physiological V(LMS) Barlow projection (yellow cusp high 0.98, blue cusp low 0.38); (c) zero-saturation normalised triangular prism (S = 0 spine, 60.0° equilateral section).

(a) 3-ch V(I) Cube

61.4° · bulge 0.000

(b) V(LMS) Barlow

Y 0.98 vs B 0.38

(c) Normalised Prism

60.0° · S = 0 spine

Optic-nerve stimulation versus colour psychology: red and fluorescent colours

Why red dominates passive high-chroma surfaces

Companion Paper 1⁷ measured 60 public-domain works (30 oils and 30 official posters) and found that 98–100 % of the highest-chroma pixels were red, clustering near the perceptual grey midpoint (median relative lightness 0.580 in Paper 1's archive survey). Conventional "colour psychology" treats this prevalence as symbolic or emotional resonance attached to the hue "red". Under the saturation-difference model, no symbolic premise is required. A passive diffuse colour that must command attention across both light and dark surroundings must maximise two quantities at once: its saturation difference ΔS from the achromatic spine, and its dual-ground lightness headroom H_L = min(|1 − L_Vnorm|, L_Vnorm). Across all six sRGB boundary primaries and secondaries (Table 4), red uniquely achieves the highest joint passive score J = H_L · S = 0.404 (against 0.322 for magenta, 0.320 for blue, 0.077 for green, 0.054 for cyan and 0.016 for yellow—a 25× gap over yellow). Yellow saturates strongly on white but collapses in lightness contrast (ΔL_W = 0.016); blue contrasts strongly against white but collapses against dark surfaces (L_V = 0.320). Red sits near the vertical centre of the response range (L_V = 0.596), delivering maximal simultaneous lightness and purity stimulation to the optic nerve.

Fluorescent colours as the decisive physical test

Fluorescent colours separate neural purity stimulation from cultural colour symbolism. Passive diffuse pigments are bounded by R(λ) ≤ 1.0 (MacAdam’s optimal-colour limit¹²). Fluorescent materials break this limit via Stokes-shift photoluminescence—absorbing short-wavelength UV and blue photons and re-emitting them in a narrow visible band so total spectral radiance factor β(λ) exceeds 1.0¹⁸. High-visibility fluorescent yellow-green and orange-red (ISO 20471¹⁸) sit physically outside the passive MacAdam solid with effective saturation S_eff = 1.35–1.65 (Table 4), driving joint white-ground visibility E_W to 2.62–3.20 (versus 1.94–2.06 for all passive pigments). Learned hue-name symbolism cannot explain why fluorescent pigments stimulate more strongly than passive pigments of the same hue name; optic-nerve purity overshoot explains it directly.

Alignment with psychophysiological arousal studies

Controlled empirical data support this purity-stimulation account. Valdez and Mehrabian¹⁶ regressed emotional ratings on standardised brightness B and saturation S, obtaining Arousal = −0.31 B + 0.60 S: saturation was the dominant positive driver of arousal (nearly double the weight of brightness), while hue effects were weaker and inconsistent. Wilms and Oberfeld¹⁷ orthogonally crossed hue, saturation and brightness while measuring skin conductance responses (SCR) and heart rate, confirming that physiological arousal rises strongly with saturation and brightness rather than folklore hue symbolism.

Quantitative checks

The luminance–saturation paradox on white

Table 1 compares physical luminance contrast, Paper 2 Barlow cone-response lightness difference ΔV_norm and raw physiological HPE-LMS chroma C_HPE against the uniform zero-saturation difference ΔS = 1.00 across the six sRGB boundary hues and three calibrated chart-palette hues (yellow 01, red 05, blue 13; Fig. 1), without invoking any legacy colour space.

Table 1 | Physical luminance contrast, Barlow cone-response difference, physiological opponent chroma and saturation difference against white (Y = 1, S = 0).

Colour Rel. Y WCAG Barlow L_V Barlow ΔVᵃ Phys. C_HPEᵇ ΔS
Yellow (#FFFF00) 0.9278 1.07:1 0.984 0.016 0.299 1.00
Cyan (#00FFFF) 0.7874 1.25:1 0.946 0.054 0.043 1.00
Green (#00FF00) 0.7152 1.37:1 0.923 0.077 0.284 1.00
Magenta (#FF00FF) 0.2848 3.14:1 0.678 0.322 0.174 1.00
Red (#FF0000) 0.2126 4.00:1 0.596 0.404 0.305 1.00
Blue (#0000FF) 0.0722 8.59:1 0.320 0.680 0.388 1.00
Palette 01 (#FFD000) 0.6637 1.47:1 0.905 0.095 0.310 1.00
Palette 05 (#FD0C00) 0.2115 4.02:1 0.595 0.405 0.303 1.00
Palette 13 (#2354D9) 0.1171 6.28:1 0.435 0.565 0.267 1.00

Note: White reference Y = 1, S = 0; zero legacy colour-space matrices used. ᵃ Normalised (V_Barlow(1) − V_Barlow(Y)) / (V_Barlow(1) − V_Barlow(0)) under Paper 2 Table 8 calibration (200 cd/m² white, L_A = 50 cd/m², μ_dark/κ = 0.03205). ᵇ Raw physiological HPE-LMS + V_Barlow opponent radius √((V_L − V_M)² + ((V_L + V_M)/2 − V_S)²).

Physical luminance contrast varies by 8.0× (1.07:1 to 8.59:1) and normalised cone-response lightness difference varies by 42.5× (0.016 to 0.680) across the six full-saturation hues—while raw physiological chroma still fluctuates 9.0× between cyan (0.043) and blue (0.388) because of L/M spectral overlap. Luminance-only rules and ad-hoc Helmholtz–Kohlrausch patches⁴˒⁵ cannot reconcile yellow's vanishing lightness contrast (ΔV_norm = 0.016) with its immediate visual prominence on white; reading white as S = 0 makes ΔS = 1.00 uniform around the entire saturated ring.

Fig. 1 | White-ground cone lightness difference ΔV_norm (solid dark bar) versus effective saturation difference ΔS_eff (coloured bar). Passive diffuse pigments stop at the MacAdam limit S = 1.00 (dashed line); fluorescent materials exceed 1.00 via Stokes-shift re-emission.

White-ground cone lightness difference versus effective saturation difference 0.0 0.5 1.0 1.5 Yel Cyn Grn Mag Red Blu Fl-Y Fl-O Passive MacAdam limit (S = 1.00)
  • Primary ink bar: ΔVnorm (lightness)
  • Colour bar: ΔSeff (saturation)

Testing the triangular-prism geometry across standalone physiological V(I) formulations

Table 2 evaluates cross-section edge straightness (maximum perpendicular deviation from the chord in (L, C) space), cusp lightness range, chroma ratio and internal triangle angles across six purely standalone V(I) constructions—with zero OKLab or CIELAB matrices anywhere (Fig. 2).

Table 2 | Cross-section geometry of standalone pure-physiology V(I) colour solids on the sRGB gamut versus ideal prism references.

Formulation L_B – L_W Cusp L_norm C max/min Bulge (D / B) Apex angle
Uncoupled 3-ch V(I) cubeᵃ 0.216–0.783 0.333 / 0.667ᵇ 1.00× 0.0000 / 0.0000 61.44° (mid 70.53°)
Phys. HPE-LMS + V_Barlow [0, 1] 0.216–0.783 0.315–0.984 8.98× 0.0490 / 0.0120 63.5° (Y) – 121.3° (C)
Phys. HPE-LMS + V_cone [30:1] 0.221–0.779 0.308–0.983 8.84× 0.0470 / 0.0118 63.2° (Y) – 121.2° (C)
Phys. HPE-LMS + V_Toe (q=0.0342) 0.000–0.779 0.424–0.987 10.01× 0.1023 / 0.0169 68.0° (Y) – 122.4° (C)
HPE-LMS + V_Barlow (span-norm)ᶜ 0.216–0.783 0.315–0.984 4.51× 0.0647 / 0.0156 54.8° (R) – 91.9° (C)
Normalised (H, L_aligned, S) prism 0.000–1.000 0.500 (flat) 1.00× 0.0000 / 0.0000 60.00° (equilateral)

Note: All V(I) rows use n = 0.74, σ_R = 1/√30 and zero borrowed OKLab or CIELAB matrices; HPE-LMS uses exact D65-normalised Y weights (0.3612 L + 0.6388 M) and raw opponent axes. ᵃ Uncoupled V(I) on [1/30, 1] (0.221–0.779) or Barlow [0, 1] (0.216–0.783): C/ΔL = √(2/3) = 0.8165 (−5.72 % from √3/2), angles (67.79°, 50.77°, 61.44°). ᵇ Primary vertices (R, G, B) at 1/3; secondaries (Y, C, M) at 2/3. ᶜ Cardinal axes scaled strictly by physical 4,288-point Rösch–MacAdam optimal-solid spans (span_b / span_a = 4.162×; zero fitted parameters).

Two algebraic facts stand out. First, when V(I) acts on three uncoupled channels, the response cube [0.216, 0.783]³ projects onto strictly straight edges (0.0000 bulge), equal chroma (1.00×) and a 61.44° apex angle across all six vertices. Second, once real physiological HPE-LMS cones replace uncoupled channels, L/M spectral overlap and L + M luminance weighting skew the solid (8.98× raw chroma ratio, 0.315–0.984 cusp range). Paper 2's smooth Barlow dark light halves dark-edge bulge relative to piecewise V_Toe (0.0490 versus 0.1023) and matches Paper 1's symmetric 30:1 range (0.0470, 8.84×); scaling the two cardinal axes strictly by their physical Rösch–MacAdam spans cuts chroma anisotropy in half (4.51×) with zero fitted parameters.

Hue-dependent lightness–saturation slopes

Table 3 quantifies how rapidly physiological opponent chroma C_HPE changes with lightness on the dark and bright sides of each primary cusp under the Paper 2 Barlow lightness scale L_Vnorm—together with the dimensionless bright-to-dark slope ratio L_Vnorm / (1 − L_Vnorm), which depends strictly on Paper 1–2 cone lightness and is invariant to any opponent scaling.

Table 3 | Dark-side and bright-side coupling slopes across the six sRGB boundary hues in standalone physiological HPE-LMS + V_Barlow.

Hue H_HPE Rel. Y L_Vnorm Dark C/L_V Bright C/(1−L_V) Bright / Dark
Yellow 89.0° 0.9278 0.984 0.304 18.311 60.1×
Cyan 229.8° 0.7874 0.946 0.046 0.804 17.6×
Green 94.7° 0.7152 0.923 0.307 3.704 12.1×
Magenta 291.3° 0.2848 0.678 0.256 0.541 2.11×
Red 68.6° 0.2126 0.596 0.512 0.755 1.48×
Blue 259.3° 0.0722 0.320 1.210 0.570 0.47×

Note: Pure physiological HPE-LMS + V_Barlow (zero OKLab or CIELAB matrices). Bright / Dark ratio = L_Vnorm / (1 − L_Vnorm) depends strictly on Paper 1–2 cone lightness and is invariant to opponent scaling.

Yellow rises gently from black (slope 0.304) and collapses steeply near white (slope 18.311, a 60.1× bright-to-dark slope ratio); blue rises steeply from black (1.210) and fades gradually toward white (0.570, ratio 0.47×). This asymmetry is the exact geometric consequence of L + M luminance weighting in physiological cones—and disappears once lightness and relative saturation S = C / C_max(L, H) are uncoupled in the normalised prism.

Dual-ground stimulation: passive red maximum versus fluorescent overshoot

Table 4 compares dual-ground lightness headroom H_L, joint passive stimulation J = H_L · S_eff, white-ground joint visibility E_W (equation (4) evaluated with the illustrative parameter α = 1.94, taken from the Valdez–Mehrabian emotional arousal slope ratio¹⁶ rather than a visual-prominence fit), and the Valdez–Mehrabian arousal index A = 0.60 S_eff − 0.31 L_V across passive primaries and two ISO 20471 fluorescent materials¹⁸.

Table 4 | Dual-ground lightness headroom, joint optic-nerve stimulation and arousal index for passive primaries versus fluorescent materials.

Stimulus Y / β_T L_V H_L S_eff J = H_L·S A (VM94)ᵃ E_W
Yellow (passive) 0.9278 0.984 0.016 1.00 0.016 +0.295 1.940
Cyan (passive) 0.7874 0.946 0.054 1.00 0.054 +0.307 1.941
Green (passive) 0.7152 0.923 0.077 1.00 0.077 +0.314 1.942
Magenta (passive) 0.2848 0.678 0.322 1.00 0.322 +0.390 1.966
Red (passive) 0.2126 0.596 0.404 1.00 0.404 +0.415 1.982
Blue (passive) 0.0722 0.320 0.320 1.00 0.320 +0.501 2.056
Fluor. Yel-Grnᵇ 1.2100 1.040 0.040 1.35 0.053 +0.488 2.619
Fluor. Org-Redᵇ 0.6083 0.884 0.116 1.65 0.192 +0.716 3.203

Note: ᵃ Valdez and Mehrabian (1994) regression A = 0.60 S − 0.31 B¹⁶ with B = min(1.2, L_V) and S = S_eff; E_W uses the illustrative parameter α = 1.94 (from emotional arousal slopes, not a visual-prominence fit). ᵇ Modelled ISO 20471 fluorescent materials¹⁸ exceeding the passive MacAdam S = 1.00 limit. Dual-ground headroom H_L = min(|1 − L_V|, L_V) is defined strictly for passive diffuse surfaces (Y ≤ 1) and is not applied to active fluorescent rows (Y > 1). Full 380–700 nm spectral integration in companion Paper 5 gives Y = 1.075 (fluorescent yellow-green) and S_eff = 1.467 (fluorescent orange-red), confirming the same MacAdam overshoot.

MacAdam (1942) chromaticity discrimination ellipses

Table 5 evaluates all 25 published MacAdam (1942) chromaticity discrimination ellipses¹⁴ at constant luminance Y = 0.50 strictly inside physical radiometry (CIE 1931 xy) and standalone physiological HPE-LMS with Papers 1–2 cone responses—zero parameters fitted to MacAdam and zero matrices borrowed from OKLab or CIELAB.

Table 5 | Isotropy of the 25 MacAdam (1942) chromaticity discrimination ellipses in radiometric xy and standalone physiological HPE-LMS (Y = 0.50; zero fitted parameters).

Coordinate formulation Area max/min Mean a/b (max) Radius CV
CIE 1931 xy (radiometric) 74.22× 2.95 (5.00) 44.7 %
Linear physiological HPE-LMS 37.58× 9.79 (38.74) 55.9 %
Phys. HPE-LMS + V_Barlow (raw) 7.96× 6.82 (26.15) 28.5 %
Phys. HPE-LMS + V_Toe (q=0.0342) 9.03× 7.22 (30.30) 31.1 %
HPE-LMS + V_Barlow (span-norm)ᵃ 7.96× 2.44 (13.34) 28.5 %

Note: 36 perimeter points per ellipse across all 25 MacAdam (1942) ellipses¹⁴ at Y = 0.50; zero fitted parameters and zero OKLab or CIELAB matrices. ᵃ Cardinal axes (L − M, (L + M)/2 − S) divided strictly by their physical 4,288-point Rösch–MacAdam optimal-solid spans (span_a = 0.2367, span_b = 0.9850, ratio 4.162×).

Passing physiological HPE-LMS cones through Paper 1–2's smooth Barlow response V_Barlow—derived purely from achromatic 30:1 surface lightness and 620 R*/s dark light—immediately slashes MacAdam ellipse area anisotropy 9.3× relative to CIE xy (74.22× down to 7.96×) and 4.7× relative to linear cones (37.58× to 7.96×), cuts radius CV from 55.9 % to 28.5 %, and outperforms piecewise V_Toe (9.03×, CV 31.1 %). Because L and M absorption spectra overlap heavily, the raw L − M axis spans 4.162× less physical range than (L + M)/2 − S across the Rösch–MacAdam optimal solid; normalising the two cardinal axes strictly by their physical optimal-solid spans drops mean ellipse aspect from 6.82 to 2.44 with zero fitted parameters. By contrast, naive polar radial division C / C_max(H) on unscaled raw opponent axes introduces an origin Jacobian singularity near white (inflating area ratio to 86.04× on near-white ellipse #13), demonstrating mathematically why cardinal-axis physical span normalisation is required near threshold while radial S = C / C_max(L, H) governs suprathreshold boundary saturation.

CIE 1931 spectral locus and Rösch–MacAdam optimal surface-colour solid

To test the geometry beyond sRGB across all physically realisable lights and passive surfaces, all 321 monochromatic wavelengths of the CIE 1931 2° standard observer (380–700 nm, 1 nm step)¹ and all 4,288 two-transition Rösch–MacAdam optimal reflectance spectra (380–700 nm at 5 nm resolution under D65)¹² were integrated directly with physiological Stockman–Sharpe 2° cone fundamentals¹¹ and HPE-LMS cone excitations, then passed through Paper 1–2 cone response V_Barlow (μ_dark/κ = 0.03205) and piecewise V_toe (q = 0.0342). Both physiological cone bases produce zero negative excitations across all 321 spectral wavelengths and all 4,288 optimal spectra, and adding the Barlow dark-light floor ensures strictly positive inputs everywhere on the physical boundary.

Table 6 | Pure physiological geometry of the 4,288-point Rösch–MacAdam optimal surface-colour solid (D65, 380–700 nm) versus the uncoupled V(I) prism.

Formulation Cusp L_norm (hue) C ratio Bulge (dark/bright) Apex (median)
Stockman–Sharpe 2° + V_Barlow [0, 1] 0.132 (265°)–0.945 (85°) 6.41× 0.0802 / 0.0767 49.6°–147.2° (105.6°)
Stockman–Sharpe 2° + V_Barlow [30:1] 0.126 (265°)–0.947 (85°) 5.99× 0.0784 / 0.0776 49.6°–146.0° (107.8°)
Stockman–Sharpe 2° + V_Toe (q=0.0342) 0.125 (265°)–0.949 (85°) 7.45× 0.0732 / 0.0830 49.2°–151.8° (102.8°)
Physiological HPE-LMS + V_Barlow [0, 1] 0.121 (275°)–0.938 (85°) 5.99× 0.0789 / 0.0797 50.0°–145.6° (119.3°)
Physiological HPE-LMS + V_Barlow [30:1] 0.099 (265°)–0.941 (85°) 5.62× 0.0874 / 0.0784 49.9°–144.0° (117.3°)
Physiological HPE-LMS + V_Toe (q=0.0342) 0.089 (275°)–0.928 (85°) 6.88× 0.0699 / 0.0932 50.1°–150.2° (118.0°)
Uncoupled V(I) cube / (H, L, S) prismᵃ 0.333–0.667 / 0.500 1.00× 0.0000 / 0.0000 61.44° / 60.00°

Note: All 4,288 two-transition spectra (65 bands, 5 nm step) were evaluated under CIE D65 across 36 ten-degree hue sectors. Stockman–Sharpe 2° uses D65-rescaled physiological luminous weights (0.6981 L + 0.3019 M) and raw opponent axes (L − M, (L + M)/2 − S); HPE-LMS uses exact D65-normalised Y weights (0.3612 L + 0.6388 M) and raw opponent axes. Zero negative cone excitations occur across all 321 spectral wavelengths and 4,288 optimal spectra. ᵃ Theoretical symmetry reference from Table 2.

Table 6 sharpens the paper's core geometric contrast across the full physical surface boundary. Under real physiological cones (Stockman–Sharpe 2° and HPE-LMS), L/M absorption overlap produces a 5.6–6.4× chroma anisotropy across the Rösch–MacAdam optimal solid under smooth Barlow dark light, rising further to 6.9–7.5× under a piecewise linear toe, while L + M luminance weighting pushes the blue cusp down to 0.10–0.13 and the yellow cusp up to 0.94–0.95. The saturation-difference formulation of equations (1)–(5) keeps these physiological cone endpoints intact and recovers a 1.00×, 60° symmetric prism directly by normalising saturation against the physical optimal envelope C_max(L, H).

Physical pigment check on the 2,734 real Munsell Renotation chips

Because the Munsell Renotation spacing (1943)¹⁵ was built under a luminance-first convention—without a 30:1 optical/Barlow black floor and without treating white as a zero-saturation reference—its 2,734 real physical pigment chips are used here strictly as measured physical reflectance–chromaticity data (Newhall, Nickerson and Judd 1943¹⁵, scaled by ASTM D1535-08e1¹⁹ factor 0.975 / 100 and Bradford-adapted from Illuminant C to D65) to expose exact, experimentally testable regime divergences between smooth Barlow cone response and piecewise V_toe. Table 7 projects all 2,734 real pigment chips directly into standalone physiological HPE-LMS + V_Barlow and V_toe.

Table 7 | Regime-by-regime analysis of all 2,734 real physical pigment chips (V = 1–9) in standalone physiological HPE-LMS + V_Barlow versus V_toe.

V (N) Y_PRD V/10 L_Vbar L_Vtoe V_Bar / Analytic V_Toe White ΔL_V
1 (196) 0.0118 0.10 0.074 0.099 0.58× / 0.61× 1.00× 0.926
2 (274) 0.0305 0.20 0.168 0.257 0.77× / 0.91× 1.28× 0.832
3 (331) 0.0639 0.30 0.295 0.405 1.01× / 1.07× 1.23× 0.705
4 (373) 0.1170 0.40 0.435 0.537 1.07× / 1.08× 1.16× 0.565
5 (390) 0.1928 0.50 0.569 0.655 1.00× / 1.00× 1.00× 0.431
6 (370) 0.2930 0.60 0.686 0.753 0.90× / 0.88× 0.85× 0.314
7 (342) 0.4198 0.70 0.786 0.834 0.78× / 0.75× 0.71× 0.214
8 (283) 0.5762 0.80 0.870 0.900 0.68× / 0.64× 0.61× 0.130
9 (175) 0.7669 0.90 0.940 0.954 0.64× / 0.53× 0.56× 0.060

Note: Pure physiological HPE-LMS with raw opponent axes (L − M, (L + M)/2 − S); zero parameters fitted and zero matrices borrowed from OKLab or CIELAB. V_Bar and V_Toe report mean radial slope C_HPE / C_Munsell across chips with C_M ≤ 8 at each Value, normalised to V = 5. Analytic evaluates Y^(2/3) V'_Barlow(Y) relative to V = 5.

Three sharp, experimentally testable findings stand out across the 2,734 real pigment chips. First, at the dark end (V = 1–2, Y ≤ 0.0305), pigment level V = 2 sits at Y_PRD = 0.0305—directly at the 30:1 realistic surface black floor (1/30 = 0.0333)—while V = 1 (Y = 0.0118) lies below it. Smooth Barlow cone response maps V = 1 smoothly to L_Vbar = 0.074 and V = 2 to 0.168 with monotonic chromatic gain (0.58× → 0.77× → 1.01×); by contrast, a piecewise linear toe (q = 0.0342) lifts V = 2 lightness sharply to 0.257 and creates a 1.28× chroma-gain discontinuity at the hard junction.

Second, at the bright end (V = 7–9, Y = 0.42–0.77), bounded Naka–Rushton receptor response V_Barlow saturates toward the white ceiling, compressing raw physiological cone chroma gain from 1.07× at V = 4 down to 0.78× (V = 7), 0.68× (V = 8) and 0.64× (V = 9)—closely tracking the analytic local-slope factor Y^(2/3) V'_Barlow(Y) (0.75×, 0.64×, 0.53×). This quantifies why raw receptor potentials require envelope-relative saturation normalisation S = C / C_max(L, H) to sustain bright-end chromatic strength.

Third, evaluating real high-chroma pigment chips directly against the exact continuous 1 nm Rösch–MacAdam optimal boundary in pure physiological HPE-LMS + V_Barlow confirms Table 1 on physical pigment data: the brightest saturated yellow chip (5Y 9/20, Y = 0.7669) has almost zero lightness contrast against white (ΔL_white = 0.060), yet achieves relative saturation S_MacAdam = 0.970 (97.0 % of the absolute physical surface limit)—higher than mid-grey red (5R 5/20: ΔL_white = 0.452, S_MacAdam = 0.957) and dark blue (5PB 3/18: ΔL_white = 0.718, S_MacAdam = 0.934).

Discussion

Relation to prior colour science

  • Optimal colour boundaries (MacAdam 1935¹²): passive reflectance spectra shrink to zero chromaticity at Y = 0 and Y = 1, enforcing the closed lightness–saturation coupling of equations (1)–(3), while fluorescent re-emission (ISO 20471¹⁸) provides the exact physical exception (β(λ) > 1, S_eff > 1).
  • Opponent and cardinal chromatic channels (Krauskopf, Williams and Heeley 1982¹³; Mullen 1985⁹; Switkes and Crognale 1999¹⁰): chromatic contrast travels on pathways separable from luminance, enabling high visibility at isoluminance (ΔL = 0) and direct cross-attribute contrast matching.
  • Helmholtz–Kohlrausch effect (Fairchild and Pirrotta 1991⁴; Nayatani 1997⁵): the failure of luminance alone to predict the perceived strength of saturated colours is reframed as measuring a two-component signal (ΔL and ΔS) on a one-component luminance axis.
  • Phenomenological equilateral triangles (NCS, Hård and Sivik 1981⁶): the empirical finding that observers partition any hue slice into whiteness, blackness and chromaticness (w + s + c = 1) matches the normalised prism geometry of equation (5) when white and black serve as the S = 0 spine.
  • Physiological arousal driven by saturation (Valdez and Mehrabian 1994¹⁶; Wilms and Oberfeld 2018¹⁷): empirical arousal data track saturation and brightness rather than symbolic hue myths, supporting the optic-nerve stimulation account of red and fluorescent colours.
  • Complete independence from legacy colour models (Stockman and Sharpe 2000¹¹; MacAdam 1942¹⁴; Newhall, Nickerson and Judd 1943¹⁵): Tables 1–7 demonstrate that physical radiometry plus Papers 1–2 cone response V_Barlow already reproduces MacAdam threshold isotropy (7.96× area spread, 2.44 mean aspect after zero-fit physical span normalisation) and confirms S_MacAdam = 0.970 on real bright yellow pigments where ΔL_white = 0.060, without borrowing a single fitted matrix from CIELAB¹ or OKLab².

What remains open and limitations

  • The cross-hue weighting function α(H) in equation (4) uses α = 1.94 here strictly as an illustrative parameter borrowed from standardised emotional arousal regressions (0.60 and −0.31)¹⁶. Emotional arousal and visual prominence are separate hypotheses that must each be fitted from their own tasks; moreover, testing whether prominence near white follows raw S, absolute chroma C = S · C_max(L, H), or full colour-difference models (CIELAB/OKLab) directly resolves equation (4)'s approaching-white discontinuity.
  • Whether direct human chromaticity bisection recovers the 61.44°/60° symmetric prism geometry or the skewed physiological LMS projection of Tables 2 and 6 remains an open experimental question.
  • Tables 5 and 7 clarify the complementary roles of two distinct normalisations on physiological HPE-LMS + V_Barlow: near threshold (MacAdam ellipses), cardinal-axis physical span normalisation removes L/M spectral-overlap aspect distortion smoothly without an origin singularity (aspect 2.44, area 7.96×), whereas at bright suprathreshold pigment levels (V = 7–9), bounded Naka–Rushton compression drops raw chromatic gain to 0.64× of mid-grey and requires envelope-relative S = C / C_max(L, H) normalisation to sustain perceived bright-colour strength.
  • Fluorescent rows in Table 4 use representative ISO 20471 radiance-factor boosts (1.35× and 1.65×) rather than full bispectral Donaldson-matrix measurements of specific dye samples.

Testable predictions and limitations

Model predictions

  • On a white ground (S = 0) under controlled 30:1 adaptation, cross-hue visual prominence matches across yellow, red, green and blue will align far more closely with constant ΔS (or E(H, L, S) in equation (4)) than with constant luminance contrast or constant Barlow ΔV_norm—including on real high-Value pigments such as 5Y 9/20 (ΔL_white = 0.060, S_MacAdam = 0.970).
  • Physiological arousal (skin conductance response, pupil dilation, saccadic capture latency) will scale monotonically with physical purity overshoot ΔS_eff across matched-hue pairs (ordinary pigment S ≤ 1 versus fluorescent sample S_eff > 1 of identical hue name), independent of cultural or linguistic labels.
  • In a direct triadic bisection task (judging the midpoint between zero-saturation white, zero-saturation black and full hue colour without luminance-matching cues), observers will report an approximately symmetric triangular cross-section (matching the 60°–61.4° prism geometry) rather than collapsing yellow toward white by the 60.1× bright-to-dark slope ratio of Table 3.
  • Under controlled 30:1 adaptation near Y = 0.012–0.031 (pigment levels V = 1–2), human dark-end lightness and chroma discrimination will track the smooth Barlow dark-light floor (L_Vbar = 0.074–0.168, monotonic chroma gain 0.58× → 0.77×) rather than the abrupt jump (L_Vtoe = 0.257, 1.28× chroma-gain discontinuity) predicted by a piecewise linear toe at q = 0.0342.

Empirical falsification criteria

  • If physiological arousal or alerting latency varied primarily with hue label while holding saturation difference ΔS_eff and luminance headroom H_L strictly equal—or if fluorescent colours failed to exceed matched passive hues once luminance alone was equated—the optic-nerve purity-stimulation thesis would be falsified.
  • If perceived visibility of chromatic patches on white scaled strictly with luminance difference ΔL, the zero-saturation anchor role of white (S = 0) would be refuted. Moreover, along a fixed-hue gamut-boundary series approaching white (S ≡ 1, C → 0, ΔL → 0), if perceived prominence decays smoothly to 0 with absolute chroma C rather than holding a nonzero plateau, then entering raw S directly into equation (4) fails the approaching-white test and visual prominence must weight saturation by C_max(L, H) (or use full colour-difference coordinates) rather than raw ΔS alone.
  • If direct perceptual bisection of whiteness, blackness and chromaticness across hues reproduced the 5.6–6.4× chroma anisotropy and severe yellow–blue skew of raw physiological LMS projections even without luminance cues, the symmetric triangular-prism hypothesis would be refuted.
  • If high-luminance (V = 7–9) suprathreshold chroma matches followed the raw Naka–Rushton receptor compression factor (0.64× relative to mid-grey) instead of envelope-relative saturation scaling, the role of S-normalisation in compensating receptor saturation would be refuted.

Methods

All quantities in Tables 1–7 were computed in Python 3.14.6 (standard library only) by a single standalone script paper3-intrinsic-hue-lightness-20261125.py (paper-saturation-prism-20261126-r2.csv) with zero matrices or transforms borrowed from OKLab or CIELAB. Analytic derivations of the orthonormal response-cube geometry (C/ΔL = √(2/3), apex angle arccos(4/√70) = 61.44°, mid-edge apex arccos(1/3) = 70.53°, edge bulge 0.0000) were verified independently by numerical sampling along 50-step chords of all six cube edges. The Barlow dark-light ratio μ_dark/κ = 0.03205 reproduces Table 8 of companion Paper 2⁸ (200 cd/m² white, L_A = 50 cd/m², D = 3.2034 mm, c_td = 12 R* cone⁻¹ s⁻¹ td⁻¹, dark light 620 R*/s). Physiological HPE-LMS cone excitations are D65-normalised with exact CIE Y weights (0.3612 L + 0.6388 M) and raw cardinal opponent axes (a = V_L − V_M, b = (V_L + V_M)/2 − V_S); physical cardinal-span normalisation in Tables 2 and 5 divides a and b strictly by their 4,288-point Rösch–MacAdam optimal-solid spans (span_a = 0.2367, span_b = 0.9850, ratio 4.162×). Table 5 transforms 36 perimeter points per ellipse across all 25 MacAdam (1942) ellipses¹⁴ at Y = 0.50 and extracts exact semi-axes via covariance eigenvalues. Table 6 integrates the official CIE 1931 2° standard observer¹ (380–700 nm, 1 nm spectral locus and 5 nm D65 bands) and Stockman–Sharpe 2° cone fundamentals¹¹ (D65-rescaled luminous weights 0.6981 L + 0.3019 M) over all 4,288 two-transition bandpass and bandstop optimal spectra¹² via exact prefix sums, evaluating both R ∈ [0, 1] and the 30:1 surface envelope R ∈ [1/30, 1] across 36 ten-degree hue sectors. Table 7 projects all 2,734 real surface pigment chips from Newhall, Nickerson and Judd (1943)¹⁵, scaled by the ASTM D1535-08e1¹⁹ factor 0.975 / 100 and Bradford-adapted from Illuminant C to D65, into pure physiological HPE-LMS + V_Barlow and V_toe; relative saturation S_MacAdam for 5Y 9/20, 5R 5/20 and 5PB 3/18 is solved on the exact continuous two-transition Schrödinger–MacAdam optimal boundary (1 nm CIE 1931 + D65, matched to < 10⁻¹² in lightness and hue).

Declarations

Data and code availability: The Vela (V-Prism 30) specification is released under CC0 1.0 Public Domain and the reference implementation under the MIT licence (github.com/ariclue/Laboratory).

Competing interests: The author declares no competing interests.

Use of generative AI: A generative AI tool was used during the preparation of this work (Gemini 4 Neon, Google). After using this tool, the author reviewed, verified and edited the content as needed and takes full responsibility for the content of this paper.

References

  • 1. CIE. Colorimetry (CIE 15:2018; ISO/CIE 11664-4:2019).
  • 2. Ottosson, B. A perceptual color space for image processing (OKLab); Two new color spaces for color picking: Okhsv and Okhsl (2020–2021).
  • 3. W3C. Web Content Accessibility Guidelines (WCAG) 2.2 — Relative luminance and contrast ratio (2023).
  • 4. Fairchild, M. D. & Pirrotta, E. Predicting the lightness of chromatic object colors using CIELAB. Color Res. Appl. 16(6), 385–393 (1991). https://doi.org/10.1002/col.5080160608
  • 5. Nayatani, Y. Simple estimation methods for the Helmholtz–Kohlrausch effect. Color Res. Appl. 22(6), 385–401 (1997). https://doi.org/10.1002/(SICI)1520-6378(199712)22:6<385::AID-COL6>3.0.CO;2-R
  • 6. Hård, A. & Sivik, L. NCS—Natural Color System: A Swedish Standard for Color Notation. Color Res. Appl. 6(3), 129–138 (1981). https://doi.org/10.1002/col.5080060303
  • 7. Alchemist, H. A geometric-mean prediction for middle grey from a cone-response model. Ariclue research (2026). doi:10.5281/zenodo.24540310
  • 8. Alchemist, H. A spatial sampling model of lightness discrimination under optical blur. Ariclue research (2026). doi:10.5281/zenodo.24540335
  • 9. Mullen, K. T. The contrast sensitivity of human colour vision to red-green and blue-yellow chromatic gratings. J. Physiol. 359, 381–400 (1985). https://doi.org/10.1113/jphysiol.1985.sp015591
  • 10. Switkes, E. & Crognale, M. A. Comparison of color and luminance contrast: apples versus oranges? Vision Res. 39(10), 1823–1831 (1999). https://doi.org/10.1016/s0042-6989(98)00219-3
  • 11. Stockman, A. & Sharpe, L. T. The spectral sensitivities of the middle- and long-wavelength-sensitive cones derived from measurements in observers of known genotype. Vision Res. 40(13), 1711–1737 (2000). https://doi.org/10.1016/s0042-6989(00)00021-3
  • 12. MacAdam, D. L. Maximum visual efficiency of colored materials. J. Opt. Soc. Am. 25(11), 361–367 (1935). https://doi.org/10.1364/JOSA.25.000361
  • 13. Krauskopf, J., Williams, D. R. & Heeley, D. W. Cardinal directions of color space. Vision Res. 22(9), 1123–1131 (1982). https://doi.org/10.1016/0042-6989(82)90077-3
  • 14. MacAdam, D. L. Visual sensitivities to color differences in daylight. J. Opt. Soc. Am. 32(5), 247–274 (1942). https://doi.org/10.1364/JOSA.32.000247
  • 15. Newhall, S. M., Nickerson, D. & Judd, D. B. Final report of the O.S.A. subcommittee on the spacing of the Munsell colors. J. Opt. Soc. Am. 33(7), 385–418 (1943).
  • 16. Valdez, P. & Mehrabian, A. Effects of color on emotions. J. Exp. Psychol. Gen. 123(4), 394–409 (1994). https://doi.org/10.1037/0096-3445.123.4.394
  • 17. Wilms, L. & Oberfeld, D. Color and emotion: effects of hue, saturation, and brightness. Psychol. Res. 82(5), 896–914 (2018). https://doi.org/10.1007/s00426-017-0880-8
  • 18. ISO. High visibility clothing — Test methods and requirements (ISO 20471:2013).
  • 19. ASTM International. Standard Practice for Specifying Color by the Munsell System (ASTM D1535-08e1, 2008).